Laserfiche WebLink
movement of the structure resulting from the <br />hydrodynamic and hydrostatic loads, including <br />the effects of buoyancy. Methods of anchoring <br />may include, but are not: to be limited to, us~ <br />of over-the-top or frame ties to ground <br />anchors. <br /> <br />Construction Materials and Methods. <br /> <br />(1) All new construction and substantial <br />improvements shall be constructed with <br />materials resistant to flood damage. <br />(2) Ail new construction and substantial <br />improvements shall be constructed using <br />methods and practices that minimize flood <br />damage. <br />(3) All new construction and substantial <br />improvements shall be constructed with <br />electrical, heating, ventilation, plumbing and <br />air conditioning equipment and other service <br />facilities that are designed and/or located'so <br />as to prevent water from entering or <br />accumulating within the components during <br />conditions of flooding. <br /> <br />(c) Utilities. <br /> <br />(1) Ali new and replacement water supply <br />systems shall be designed to minimize or <br />eliminate infiltration of flood waters into <br />the systems; <br />(2) New and replacement Sanitary sewerage <br />systems shall be designed to minimize or <br />eliminate infiltration of flood waters into <br />the systems and discharge from the systems <br />into the flood waters; and <br />(3) Individual waste water treatment systems <br />shalI be located to avoid impairment to them <br />or contamination from the~ during flooding. <br /> <br />(d') Subdivision Proposals. <br /> <br /> (1) All subdivision proposals, including <br />manufactured home subdivisions, shall be <br />consistent with the need to minimize flood <br /> <br />(2) All subdivision proposals, including <br />manufactured home subdivisions, shall have <br />public utilities and facilities such as sewer, <br />gas, electrical, and water systems located and <br />constructed to minimize flood damage. <br />(3) All subdivision proposals, including , <br />manufactured' home subdivisions, Shall have <br />adequate drainage provided to reduce exposure <br />to flood damage; and <br />(4) Base flood elevation data shall be <br />provided for subdivision proposals, including <br />manufactured home subdivisions, and other <br />proposed developments, which contain at least <br />50 lots or 5 acres (whichever is less). <br /> <br />1308.19 SPECIFIC STANDARDS. <br /> <br />In all areas of special flood hazards where base <br />flood elevation data have been provided as set <br />forth in Section 1308.07, the following provisions <br />are required: <br /> <br />10 <br /> <br /> <br />