My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
S. 30-2022 - Enact 1306.76 Backflow Prevention & Cross Contamination
Document-Host
>
City of Lakewood
>
Ordinances
>
2022
>
S. 30-2022 - Enact 1306.76 Backflow Prevention & Cross Contamination
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 10:03:42 AM
Creation date
10/24/2022 9:49:47 AM
Metadata
Fields
Template:
Office Of Council
Document Type
Dockets
Number
30-2022
Date Adopted
10/17/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. A low suction throttling valve on the booster pump discharge, which throttles the <br />discharge of the pump when necessary so that suction pressure will not be reduced below <br />ten pounds per square inch gauge while the pump is operating; or, <br />2 The fire pump is equipped with a variable speed suction limiting control on the booster, <br />or fire, pump. The speed control system must be used to maintain a minimum suction <br />pressure of ten pounds per square inch gauge at the pump inlet by reducing the pump <br />driver speed while monitoring pressure in the suction piping through a sensing line. <br />C . It shall be the duty of the water consumer to maintain the low pressure cut-off device ,low <br />suction throttling valve, or variable speed suction limiting control, in proper working order <br />and to certify to the Building Commissioner, at least once every twelve months that the <br />minimum pressure sustaining method in place is operating properly. <br />Section 12. Violations. <br />A. The Building Commissioner shall deny or discontinue, after reasonable notice to the <br />occupants thereof, the water service to any premises wherein any backflow prevention device <br />required by these regulations is not installed, tested and maintained in a manner acceptable <br />to the Building Commissioner, or if it is found that the backflow preventer has been removed <br />or by-passed, or if an unprotected cross -connection exists on the premises, or if the minimum <br />pressure sustaining method required by these regulations is not installed and maintained in <br />working order. <br />B . water service to such premises shall not be restored until the consumer has corrected or <br />eliminated such conditions or defects in conformance with these regulations and to the <br />satisfaction of the Building Commissioner. <br />
The URL can be used to link to this page
Your browser does not support the video tag.