§ 1591.32 <br />DWELLING HOUSE CODE <br />92 <br />serving flames and lighting the furnaces from <br />such space, shall not be installed in floors of <br />combustible construction unless specifically <br />approved by the Building Official for such <br />installation and installed in accordance with <br />the conditions of such approval. <br />1591.32 Clearances for furnaces. <br />(a) To unprotected and protected con- <br />struction. No warm-air furnace, hot-water <br />boiler, or steam heating boiler shall be lo- <br />cated nearer than 24 inches in any direction <br />to combustible material, or combustible base <br />of plastered construction, except that this <br />distance may be reduced to: <br />i. 12 inches, when such heating appliance <br />is enclosed in a jacket or casing providing <br />an air space, or is insulated in a manner ap- <br />proved by the Building Official, or <br />ii. 12 inches, where the combustible con- <br />struction within 24 inches of the heating <br />appliance is protected with 3/s" gypsum <br />board under i/s" cement-asbestos board, or <br />3/4' gypsum or portland cement plaster on <br />metal or wire lath, or r/z" gypsum plaster on <br />3/s" gypsum lath, or other material having a <br />fire-resistance rating of not less than s/4 hour. <br />iii. 6 inches, when there is compliance with <br />both paragraphs (i) and (ii) of this sub- <br />section. <br />(b) Required for operation. No clearance <br />distance'shall, in any location, be less than <br />that required to operate, service, inspect and <br />maintain properly the heating device and its <br />accessory equipment. Hand-fired heating ap- <br />pliances shall have a minimum clearance of <br />48 inches in_ front of the firing door and the <br />ash pit door. <br />1591.33 Clearance for space heaters, stoves, <br />and ranges. <br />(a) General. The clearances for space <br />heaters, stoves or ranges burning the normal <br />fuel gases shall conform to the. ASA Stand- <br />ard Installation of -Gas Piping and Gas Ap- <br />pliances in Buildings, ASA 221.30. <br />(b) Unprotected and protected combus- <br />tible construction. No space heater, stove or <br />range burning liquid or solid fuel shall be <br />placed within 24 inches of combustible con- <br />structionnor within 18 inches of combustible <br />supports or combustible base of plastered <br />construction. These distances may be re- <br />duced one-half where such construction is <br />protected by a shield of galvanized or bright <br />reflecting metal or other equivalent noncom- <br />bustible material extending from the floor <br />to 1 foot above and 1 foot beyond the sides of <br />such appliances: <br />(c) Provide access to attached fuel tanks. <br />Space heaters, stoves, and ranges burning <br />liquid fuel which have an attached fuel tank <br />shall be installed with sufficient clearance to <br />provide direct and easy access to the fuel <br />tank and shall have ashut-off valve between <br />the tank and the heater, stove or range. <br />1591.34 Clearances for ceiling-type direct- <br />fired unit heaters. <br />(a) Unprotected and protected combus- <br />tible construction. Ceiling-type, direct-fired <br />unit heaters shall in all cases be equipped <br />with the automatic controls specified in Sec- <br />tions 159122 to 159129 inclusive and, except <br />as herein provided, shall have clearances of <br />not less than 18 inches from combustible <br />material or combustible base of plastered <br />construction. When combustible construc- <br />tion is protected as set forth in subsection <br />1591,32 (a) ii, the clearance distance may be <br />reduced to 6 inches or to such lesser dis- <br />tance as may be approved in subsection (b) <br />of this Section. <br />(b) Permissible reduction. Ceiling-type <br />direct-fired unit heaters which have been <br />tested by an accredited testing agency and <br />approved by said agency for installation with <br />lesser clearances than specified in subsection <br />(a) of this Section may be installed with <br />clearances specified in such approval unless <br />and until otherwise ordered by the Board of <br />Building Code Appeals. <br />1591.35 Direct-fired wall heaters. <br />Direct-fired heaters shall not be installed <br />in walls of combustible construction unless <br />approved by the Board of Building Code <br />Appeals. <br />1591.36 Clearance for steam or hot water <br />unit heaters. <br />Steam or hot water unit heaters shall be <br />installed to provide clearances of not less <br />than 1 inch from all heated portions thereof <br />to combustible material, whether plastered <br />or unplastered. <br />1591.37 Controls for existing heating instal- <br />lations. <br />Whenever an existing furnace is rein- <br />stalled, replaced, moved, converted for use <br />of other fuel from that previously used, or <br />otherwise materially altered, it shall be <br />equipped with a temperature limit control <br />operating as specified for new installations <br />in Sections 1591.22 to 1591.29 inclusive, ex- <br />cept that existing temperature limit controls <br />may be retained without change. <br />® • 33 National Standards § 1521.29 <br />1521.23 National Warm Air Heating and.Air Conditioning Association. <br />Manual 3-1950 Measuring Heat Losses. <br />Manual 5-1950 Design and Installation of Gravity Warm Air Heating Systems, <br />Manual 7-1950 Design and Installation of Warm Air Winter Air Conditioning Sys- <br />tems. <br />Manual ?-A 1950 Design and Installation of Warm Air Ceiling Panel Systems. <br />Manual 8-1948 Yardstick for Classifying Warm Air Wintea• Air Conditioning Sys- <br />tems. <br />1521.24 Standards of the Steel'Joist Institute. <br />Oct, 20/49 Standard Specifications for Open Web Steel Joist Construction. <br />1521.25 Publications of the Underwriters' Laboratories, Inc. <br />May 1952 ~ Electrical Equipment List. <br />Jan. 1952 Fire Protection Equipment List. <br />Nov. 1952 Gas and Oil Equipment List. <br />Subject 723 Standard Test Method for Fire Hazard Classification of Building <br />August 1950 Materials. <br />1521.26 Army and Navy specifications. <br />MIL-A-5534 Military Specifications: <br />Jan. 1950 Adhesive; High Temperature Setting Resin (Phenol, Melamine, <br />and Resorcinol Base). <br />JAN-A-397 Joint Army-Navy Specification: <br />Sept. 1946 Adhesive; Thermosetting-Resin, Room-Temperature and Interme- <br />Amend. 10/48 diate-Temperature Setting, Waterproof (Phenolic, Resorcinol, <br />and Melamine Base) (for Wood) . <br />152127 Commercial Standards of the Department of Commerce. <br />CS 4-29 _ Staple Porcelain (All Clay) Plumbing Fixtures. <br />CS 20-49 Vitreous China Plumbing Fixtures, <br />CS 31-38 Wood Shingles (fourth edition). <br />CS 35-49 Hardwood Plywood (fourth edition) . <br />CS 42-49 Structural Fiber Insulating Board <br />CS 45-48 Douglas Fir Plywood (eighth edition} , <br />CS 48-40 Domestic Burners for Pennsylvania Anthracite (Underfeed Type) . <br />CS 75-42 Automatic Mechanical Draft Oil Burners Designed for Domestic <br />Installations. <br />CS 77-51 Enameled Cast-Iron Plumbing Fixtures. <br />CS 99-42 Gas Floor Furnaces; Gravity Circulating Type. <br />CS101-43 Flue-Connected Oil-Burning Space Heaters Equipped with, Vapor- <br /> izing Pat-Type Burners. <br />CS104-49 Warm-Air Furnaces Equipped with Vaporizing-Type Oil Burners, <br />CS109-44 Solid-Fuel-Burning Forced-Air Furnaces. <br />C5111-43 Earthenware (Vitreous-Glazed) Plumbing Fixtures. <br />CS113-44 Oil Burning Floor Furnaces Equipped with Vaporizing Pot-Type <br /> Burners. <br />CS116-44 Bituminized Fiber Drain and Sewer Pipe. <br />CS125-47 Prefabricated Homes (second edition). <br />1521.28 Federal Housing Administration; <br />Housing and Home Finance Agency. <br />FHA-2550 Tables of Maximum Allowable Spans for Wood Floor Joists, Ceiling <br />March 1950 Joists, Rafters, in Residential Construction. <br />HHFA Performance Standards; Structural and Insulation Requirements <br />June 1947 for Houses. <br />1521.29 Federal Specifications, General Services Administration. <br />• • C-G-456-1941 Casein-Type Water Resistant Glue. <br />C-G=496-1944 Resin Type (liquid and powder) Glue. <br />