Laserfiche WebLink
<br />§ 1545.25 <br />DWELLING HOUSE CODE <br />iii, The longitudinal members of the <br />frames shall have a nominal thickness of <br />not less than twice that of the covering. <br />iv. Spaced headers for lateral support <br />shall be provided between longitudinal <br />members when such members have a ratio <br />of height to thickness of more than two to <br />one. <br />1545.25 Spacing of vertical staAds. <br />Maximum stud spacing for bearing-wall <br />and partition sheathing and for use in <br />stressed skin panels or other prefabricated <br />construction shall be determined by en- <br />gineering analysis or by test prescribed for <br />prefabricated assemblies in Section 1555.05. <br />For yard lumber, the vertical loads shall not <br />exceed the limits specified in TABLE 45C ex- <br />54 <br />cept as otherwise provided in Section <br />1545,03, When stress grade materials are <br />used, the stresses and design shall conform <br />to the NLMA National Design Specification <br />for Stress C~•ade Lumber and its Fastenings, <br />or other accepted engineering practice. <br />1545.26 At-grade protection. <br />All exterior structural and non-load-bear- <br />ing wood frame work shall be supported on <br />the foundation walls not less than 6 inches <br />above the finished grade. All untreated wood <br />sill plates shall be isolated from masonry or <br />concrete with waterproof felt or corrosion- <br />resistive metal or shall be bedded in a ce- <br />ment mortar topping which shall be finished <br />to provide a true and even bearing, <br />CHAPTER 47. STRUCTURAL STEEL AND IRON. <br />1547.01 Material. <br />(a) Structural Steel. Structural steel <br />shall conform to ASTM A 7. <br />(b) Rivet Steel. Rivet steel shall conform <br />to ASTM A 141, <br />(e) Joists Formed of Strip or Sheet Steel. <br />Steel joists and light gage formed steel struc- <br />tural members shall be formed of steel con- <br />forming to ASTM A 245, ASTM A 246, or <br />ASTM A 303 and shall be of a quality at least <br />equal to Grade C under the applicable <br />standard. <br />(d) Cast Iron. Cast iron shall conform to <br />ASTM A 48, and shall have a minimum ten- <br />sile strength of 20,000 psi. <br />(e) Stock Materials, Stock materials shall, <br />be of a quality equal to that called for by <br />subsection (a) of this Section. Mill test re- <br />ports shall constitute a sufficient record as to <br />the quality of material taken from stock. <br />(f) Welding Rods. Arc-welding electrodes <br />shall conform to ASTM A 233. Gas-welding <br />rods shall'conform to ASTM A 251. <br />T 547.02 Design and erection of steel. <br />Structural steel design and erection shall <br />be in accord with the RISC Specification for <br />the Design, Fabrication.. and Erection ,of <br />S.tructur¢l_,Steel for Buildings. Steel joist <br />construction shall be designed and erected in <br />conformity .with the provisions of ASA <br />A87.I. ~ Open web steel joist design and erec- <br />tion shall be in accord with Steel Joist In- <br />stitute Standard Specifications for Open Web <br />Steel Joist Construction, Light gage formed <br />steel: structural members shall be designed <br />in accord with the AISI Light Gage Steel <br />Design Manual and AISI Bulletin V-Steel <br />Regulations. <br />1547.03 i~'eflding, <br />The technique of welding employed, the <br />appearance of quality of welds made, and the <br />methods used in correcting defective work <br />shall conform to the American Welding. So- <br />ciety Code for Arc and Gas Welding in <br />Buildi~ag Construction. Welds shall be made <br />only by operators who have been previously <br />qualified by tests prescribed in American <br />Welding Society Standard Qualification Pro- <br />cedure and certified as provided under the . <br />applicable provisions for registrations, li- <br />censing and certificate of qualification in <br />Chapter 15, to perform the type of work re- <br />quired, except that this provision need not <br />apply to tack welds not later incorporated <br />into finished welds .intended, to carry cal- <br />culated stresses. <br />1547.04 Design of cast-iron. <br />Cast-iron structural members shall be de- <br />signed. so that the maximum static stresses <br />shall not.exceed 3000 psi in tension or shear, <br />16000 psi in compression in bending, and in <br />compression on columns 9000 psi .minus 40 <br />L/R, where L is the length in inches and R <br />is the least radius of gyration, with L/R not <br />exceeding 70. Cast-iron columns shall have <br />a minimum thickness of metal of 1/12 the <br />diameter or least dimension of cross=section, <br />with a minimum thickness of 3/4 inch. The <br />outside diameter of a cast-iron column shall <br />be at least 5 inches: Cast-iron lintels shall <br />have a minimum thickness of 3/4 inch and <br />shall not iie used for spans exceeding 6 feet, <br /> <br />• • <br />• ~ <br />71 <br />Glazing and Glass Block <br />§ 1571.03 <br />24 inches each side of such openings or be <br />of equivalent length with hooks. The rein- <br />forcement, both above and below, shall be <br />equivalent to one 5/s inch round rod for <br />each 6 inches or fraction thereof of wall <br />thickness, <br />1569.04 Stone, <br />The minimum thickness of 'walls of stone <br />ashlar shall be not less than. that required <br />for solid masonry walls under Section <br />1569,02. Rubble stone walls shall be not <br />less than 16 inches thick. In ashlar masonry,, <br />bond stone uniformly distributed shall be <br />provided to the extent of not less than 10 <br />per cent of the area. Rubble stone masonry <br />shall have bond stones with a maximum <br />spacing of 3 feet vertically and horizontally. <br />1569.05 Structural clay file and hollow con- <br />crete masonry units. <br />Walls of structural clay file or hollow <br />concrete masonry units shall have a.thick- <br />ness of not less than that required for plain <br />solid masonry walls as set forth in Section <br />1569.02, subject to the requirements for <br />bracing.tabulated in Section 1569.01. When <br />laid with cells vertical; hollow masonry units <br />shall have full mortar coverage of the face <br />shells in both the horizontal and vertical <br />joints;,when laid with cells horizontal, units <br />shall be bedded solidly in mortar and joints <br />between contiguous face shells shall be filled <br />solid with mortar. Where two or more hol- <br />low units are used to make up the thickness <br />of a wall, the stretcher courses shall be <br />bonded.at vertical intervals not exceeding <br />34 inches by a course lapping at least 33/4 <br />inches beyond the unit below, or by lapping <br />with units at least 50 per cent greater in <br />thickness than the units .below at vertical <br />intervals not exceeding 17 inches, <br />1569.06 Cavity walls and hollow walls. of <br />solid units. - <br />(a) Thickness and height. Cavity walls <br />and hollow walls of solid masonry.units shall <br />be not less in thickness than required for <br />plain solid masonry in Section 1569.02, sub- <br />ject to the requirements for bracing tabu- <br />lated in Section 1569.01, and provided fur- <br />ther that 10-inch cavity .walls shall not ex- <br />ceed 25 feet in height above the support of <br />such cavity walls. <br />(b) Cavity wall construction. In cavity <br />walls, neither the facing nor backing shall be <br />less than 33/4 inches in nominal thickness, <br />and the cavity shall be not less than 2 inches <br />nor more than 3 inches in width. The facing <br />and backing shall be tied together with <br />bonding ties of at least 3/16 inch diameter <br />steel rods or metal ties of equivalent stiff= <br />ness, coated with a noncorroding metal or <br />other protective coating; one:of which shall <br />be used for each 3 square feet of wall sur- <br />face. Where hollow masonry units are laid <br />with the cells vertical, rectangular ties shall <br />be used; in other walls, the ends of metal rod <br />ties shall be bent to 90° angles to provide <br />hooks not less than 2 inches long. Metal ties <br />shall be embedded in horizontal joints of the <br />facing and backing. Additional bonding ties <br />shall be provided at all openings, spaced not <br />more than 3 feet apart around the perimeter <br />and within 12 inches of the opening. Cavity <br />walls of plain concrete shall be reinforced <br />as provided in Section 1569.03. The cavity <br />shall be kept clear of mortar droppings or <br />other materials. Approved flashing shall be <br />installed and drainage (seep holes) provided <br />at the base of the cavity to keep water and <br />dampness away from the backing. <br />(c) Construction of hollow walls of solid <br />units: In hollow walls of solid masonry <br />miits, such as rolock walls or bonded hollow <br />walls, the facing and backing shall be tied <br />together with headers or bonding units as <br />required for solid masonry walls so that the <br />parts of the wall will exert common action <br />under the load.. A course of -solid masonry <br />shall be placed at the top of such walls and <br />under joists and beams. <br />CHAPTER 71: GLAZING AND GLASS SLOCK. <br />1571:01 Quality of glass panes. <br />Each glass pane shall be factory-labeled <br />as to quality. Glass shall be not less than <br />single strength, B quality, except that in <br />doors, double strength shall be required for <br />panes with~least dimension greater than 12 <br />inches, <br />cured in place with glazing beads, points or <br />sprigs and -faced-puttied. Glass set in metal <br />sash shall be back puttied and secured with <br />glazing clips, metal molds or strips; unless <br />otherwise approved by the Building Official: <br />Glass 'set iri doors shall be bedded in putty <br />and secured with molds or strips, <br />1571.02 Installation of glass panes. 1571,03 Glass 'block construction-general. <br />Glass set in wood windows shall, be. se- Glass black construction may be used in <br />