My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016 024 Ordinance
DOcument-Host
>
Mayfield Village
>
Ordinances Resolutions
>
2016 Ordinances
>
2016 024 Ordinance
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 4:11:57 PM
Creation date
9/11/2018 6:35:18 AM
Metadata
Fields
Template:
Legislation-Meeting Minutes
Document Type
Ordinance
Number
024
Date
12/19/2016
Year
2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
~~~_~ C: F4d~.GEh.€E+3 <br />~~..~ 4Z1VElfi. <br />yam'""""' V'~,h~'E~S ~C E €3 <br />~' ~~ ~~;~T~E~~ Nr~y Zo16 <br />Partnership (TARP) testing protocol. <br />b. The water quality volume discharge rate from the selected SCM is reduced to <br />prevent stream bed erosion, unless there will be negligible hydrologic impact to <br />the receiving surface water of the State. The discharge rate from the SCM will <br />have negligible impacts if the applicant can demonstrate one of the following <br />conditions: <br />(1) The entire water quality volume is recharged to groundwater. <br />(2) The development will create less than one acre of impervious surface. <br />(3) The development project is a redevelopment project with an ultra-urban <br />setting, such as a downtown area, or on a site where 100 percent of the <br />project area is already impervious surface and the stormwater discharge <br />is directed into an existing storm sewer system. <br />(4) The stormwater drainage system of the development discharges directly <br />into a large river of fourth order or greater or to a lake, and where the <br />development area is less than 5 percent of the water area upstream of the <br />development site, unless a TMDL has identified water quality problems <br />in the receiving surface water of the State. <br />D. Stormwater Quantity Control: The Comprehensive Stormwater Management Plan shall describe <br />how the proposed SCMs are designed to meet the following requirements for stormwater quantity <br />control for each watershed in the development: <br />The peak discharge rate of runoff from the Critical Storm and all more frequent storms <br />occurring under post-development conditions shall not exceed the peak discharge rate of <br />runoff from a 1-year, 24-hour storm occurring on the same development drainage area <br />under pre-development conditions. <br />2. Storms of less frequent occurrence (longer return periods) than the Critical Storm, up to <br />the 100-year, 24-hour storm shall have peak runoff discharge rates no greater than the <br />peak runoff rates from equivalent size storms under pre-development conditions. The 1, <br />2, 5, 10, 25, 50, and 100-year storms shall be considered in designing a facility to meet <br />this requirement. <br />3. The Critical Storm for each specific development drainage area shall be determined as <br />follows: <br />Determine, using a curve number-based hydrologic method or other hydrologic <br />method approved by the Village Engineer, the total volume (acre-feet) of runoff <br />from a 1-year, 24-hour storm occurring on the development drainage area before <br />and after development. These calculations shall meet the following standards: <br />(1) Calculations shall include the lot coverage assumptions used for full <br />build out as proposed. <br />24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.