My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002-056 Ordinance
Document-Host
>
City North Olmsted
>
Legislation
>
2002
>
2002-056 Ordinance
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2014 4:03:03 PM
Creation date
12/30/2013 9:16:30 AM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2002-056
Legislation Date
5/21/2002
Year
2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
APPENDIX B <br />PUMP STATIONS INFLUENT CONTROL GATES PROJECT <br />Scope of Services <br />A. Intent of the Design Professional Services: The City has prepared this RFP with <br />the intention of retaining the services of a design professional firm to: <br />1. Prepare one set of updated Dover Pump Station drawings based on the 1965 <br />record drawings and that includes the Work shown in the 1995 Emergency <br />Generator Set Project drawings and the 1998 Wet Well Enclosure Project <br />drawings; <br />2. Prepare one set of updated Lebern Pump Station drawings based on the 1961 <br />record drawings and that includes the Work shown in the 1978 Emergency <br />Generator Set Project drawings, the 1991 Discharge Piping Improvements <br />Project drawings and the 1999 Electrical Distribution Improvements <br />schematics; <br />3. Design of a manually operated, downward closing gate to be mounted over the <br />21-inch diameter influent sewer in the Dover Pump Station wet well as well as <br />the gate stem, stem guides, ma.nual operator and manual operator support <br />beams; and <br />4. Design of a manually operated, downward closing gate to be mounted over the <br />18-inch diameter influent sewer in the Lebern Pump Station wet well as well as <br />the gate stem, stem guides, manual operator and ma.nual operator support <br />beams. <br />B. Basic Scope of the Design Professional Services: In providing the Scope of <br />Services, the design professional firm will place special emphasis on: <br />1. Demonstrated ability to convert existing record drawings to electronic drawings <br />using a version of AutoCADO compatible with the Version 12 software owned <br />by the City; <br />2. Demonstrated ability to modify existing sanitary sewers and wet well structures <br />- in order to allow for the mounting of downward closing gates; and <br />3. Demonstrated ability to meet project schedules. <br />C. Specific Scope of the Design Phase Services: Tn providing the Scope of Services, <br />the design prafessional fum shall include the following specific duties: <br />1. Prepare a set of updated Dover Pump Station drawings.
The URL can be used to link to this page
Your browser does not support the video tag.