Laserfiche WebLink
SpeC1fiCatlOriS <br />The valves shall be located behind the panel with a handwheel type control extended to the <br />outside of the side pump paneL Bleeders shall be located in a horizontal line at the bottom of <br />the pump paneL They shall be properly labeled identifying the discharge they are plumbed in <br />te. The water discharUed by the bleeders shall be routed below the chassis fraine rails. <br />ELBOWS, L,EFT SIDE OUTL,ETS <br />The one (1) dischaige outlet, located on the left side pump panel, shall be furnished with a <br />2.50"(F) National Standard hose thread x 3.078 X 8 Cleveland standard, chroine plated, 45 <br />dearee elbow. <br />The 1.50" discharae outlets, located on the left side pump panei, shall ilot require 45 degree <br />elbows. <br />ELBOWS, RIGHT SIDE OITTLETS <br />The 2.50" discharge outlets, located on the right side pump paneL shall be furnished urith a <br />2.50"(F) National Standard hase thread a 3.078 X 8 Cleveland standard, clu-oine plated, 45 <br />&2ree elbow. <br />The 1.50" discharae outlets, located on the right side pump panel, sha11 not require 4-5 deLyree <br />elbows. ` <br />ELBONN'S. REAR OUTLETS <br />The 2.50" discharcye outlets, located at the rear of the apparatus, shall be fuinished with a <br />?.50"(F) National Standard hose thread x 2.50" 3.078 X 8 Cleveland standard, chrome plated, <br />30 dearee elbow. <br />EI,SONV. 3.50" OU'I'LE,T <br />Ti1e 3.50" outlet shall be furnished with a 3.50"(F) Natioilal Standard hose t1u-ead x 5.00" <br />Storz elbow adapter with Storz cap. <br />DISCHARGE OUTLET CQNTROLS <br />The disehar2e outlets sha11 incoiporate a quarter-tui71 ball valve with the control located at the <br />pump operator's pane?. The valve operating mechailism shall indicate the position of the <br />valve or an indicator shalI be provided to show when the vaive is closed. <br />DELUGE RISER - <br />A 3.00" deluge riser shall be installed above the pump in such a manner that a monitor can be <br />mounted and used effectively. Piping shall be installed securely so no movement develops <br />when the line is charged. The riser shall be gated and controlled at the pump operator's panel. <br />The outlet shall include an Akron valve with a handwheel control. <br />:VIONITOR <br />Ai1 Akron Model 342 3) moilitor shall be properly installed on the deluQe riser. The monitor <br />shall include shaper tube, Akrarl Model 3488 (aluminum) and Al-cron Tips Model 489 <br />(aluminum), 2 1i2" treads, bores 2' and 1 3/4". This nzonitor shall include both a fixed <br />Bidder <br />CompIies <br />I'es f No <br />Patre 52