Laserfiche WebLink
Attachment 1 : 2015 Blower Building Roof Specifications: <br /> All roofing systems shall conform to the building specifications Contained in <br /> the May 2012 WWTP Phase 2 Improvements- Contract A as specified <br /> below: <br /> Hazen and Sawyer, Engineers for the City of North Olmsted WWTP <br /> Improvement Project, Phase 2. <br /> SECTION 07510 <br /> BUILT-UP BITUMINOUS ROOFING <br /> PART 1 -- GENERAL <br /> 1.01 THE REQUIREMENT <br /> A. Furnish all labor, materials, equipment and appliances required for the complete execution <br /> of Work shown as specified herein. <br /> 1.02 RELATED WORK SPECIFIED ELSEWHERE (see below) <br /> A. Section 06100 - Rough Carpentry <br /> B. Section 07210 - Building Insulation <br /> C. Section 07600 - Flashing and Sheet Metal <br /> D. Section 07700 - Roof Specialties and Accessories <br /> 1.03 REFERENCE SPECIFICATIONS, CODES, AND STANDARDS <br /> A. Without limiting the generality of these specifications Work shall conform to the applicable <br /> requirements of the following documents: <br /> 1. ASTM D41 Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing. <br /> 2. ASTM D312 Asphalt Used in Roofing. <br /> 3. ASTM D2178 Asphalt Felt Used in Roofing and Waterproofing. <br /> 4. FS HH-I-1972/GEN Insulation Board, Thermal, Faced, Polyurethane or <br /> Polyisocyanurate. <br /> 1.04 SUBMITTALS <br /> A. In accordance with the procedures and requirements, submit the following: <br /> 1. Product data for glass fiber ply sheet, modified bitumen sheet membrane, insulation and base <br /> flashing materials. <br /> 2. Manufacturer's installation instructions. <br /> 3. Certification that materials meet or exceed specified requirements. <br /> 4. Certification that installer is approved by the manufacturer. <br /> 5. Copy of manufacturer's 20 year system warranty. <br /> 6. Samples of each product. <br /> 7. Color samples of cap sheet. <br /> 8. Field report at the end of all roofing and related work. <br /> 1.05 QUALITY ASSURANCE <br /> A. Applicator: Company well experienced in modified bitumen roofing membrane application <br /> and approved by product manufacturer. <br /> B. Products and installation shall be in accordance with the following: <br /> 1. Underwriters Laboratories, Inc. (UL): Class A Fire Hazard Classification. <br /> 2. Factory Mutual Engineering Corporation (FM): Roof assembly classification, FMRC, Approval <br /> Standard 4470, Class I, and 1-90 approvals. <br /> 3. Design roof to meet wind design criteria in the Ohio Building Code. <br />