RDH 1593.63 MinTmum Sizes of Und~.rground Building Drains (Amended) <br /> <br />Building drains or parts thereof installed underground or below <br />a basement or cellar floor shall be of pipe not less than two <br />(2) inch diameter. <br /> <br />RDN 1593.97 Certificate of Approval (RePealed) <br /> <br />Section 1593.97 is hereby repealed. <br /> <br />RDH 1595.03(b) Approved Standards for Equipment and Installations <br />(Amended) <br /> <br />(b) Safe practice. Except as provided in the Dwelling House Code <br />or in statutes or regulations promulgated by authority of statute, <br />or in ordinances, conformity with the requirements of the following <br />standards and the same as shall be amended from time to time will <br />be recognized as conformity with acceptance safe practice: <br /> <br />~isting; Approval and Installation Requirements for gas-burning <br />appliances and accessories~ as listed in Section 1591.07. <br />Listing,.Approval and'Installation Requirements for gas-burning <br />appliances and accessories, as established by the American <br />Standards Association, as follows: <br /> <br />Built-iQ Domestic Cooking Units, Z21.1.2 <br />Gas Hose for Portable Gas Appliances, ASA Z21.2 <br />Type I Clothes Dryers, Vol. 1, ASA Z21.5.1 <br />Manually Operated Gas Valves, ASA Z21.15 <br />Refrigerators Using Gas Fuel, ASA Z21.19 <br />Automatic Burner Ignition and Safety Shutoff <br /> Devices, ASA Z21.20 <br />Automatic Valves for Gas Appliances, ASA Z21.21 <br />Metal Connectors for Gas Appliances, ASA Z21.24 <br />Gas Appliances and Gas Piping, ASA Z21.30; NFPA No. 54 <br />Quick-Disconnect Devices for Use with Gas Fuel, ASA Z21.41 <br />Flexible Connectors of Other than, All-Metal Construction <br /> for Gas Appliances, ASA Z21.45 <br /> <br />RDH 1595.06(c) InstallatTon and Connection of Gas-fired Appliances <br /> <br />'(Enacted) <br /> <br />(c) The depth of all underground gas lines shall be subject to <br />the approval of the Building Official and shall'not be less than <br />eighteen (18) inches underground. <br /> <br />RDH 1597.01 National Electrical Cod~ (Amended) <br /> <br /> Except as otherwise provided in this Dwelling House Code, or iQ <br />statutes, or in rules or regulations promulgated by authority of statute~ <br />all electrical wiring and equipment installed in or about any building shall <br />be in accordance with the provisTons of the Nat.ional Electrical Code, as may <br />be amended from time to time. <br /> <br />RDH 1597.02 Definitions (Amended) <br /> <br /> Except as may be otherwTse stated in this Dwelling House Code, the <br />definitions set forth in said National Electrical Code, as may be amended from <br />time to time, shall apply for all electrical work under this Dwelling House Code. <br /> <br />-6- <br /> <br /> <br />