Laserfiche WebLink
ficient distance to insure proper bonds. Siaty (60) diameters for medium steel bars, <br />a.nd seventy (70) diameters for,high tensile steel rods will be considered a sufficient <br />lergth to .develop same.- -Forty (40) to fifty. (50) dianieters may be considered, f=or twis- <br />ted or deformed bars. - ' <br />,. , . <br />In all .case's, however, beams and girders v:hich are built monolithic at the <br />supports shall have at,least twenty (20) per cent asmzch steel ii1 the top over sup- <br />ports as at the center. For concentrated loads on continuous beams or girders, the <br />ber_ding moment at the center shall be calculated as for a single beam andthis moment <br />may be reduced twenty, (20) _per, cent for- intermediate ?spa.ns or ten (10) per cent for <br />er_d -spans. <br />VJhere a short span adjoins a long span and one-half (2) of the sh ort sp an con- <br />sidered as a cantilever cannot produce a, bending moment which will deeelop the strength <br />of the reinforcement over the supports the long span shall be considered as an.end <br />span. . <br />For simple girders, beams or slabe the span shall be taken as the clear sp an <br />and for continuous girders, beams or slabs the span shall be taken as t he distEnce be- <br />tween centers of supportso <br />Sec.129. I,ITlfITING -NIDTH OF FI,ANGE I1V THE BMIS. When beams ar.e made monolithic <br />with the floor slab a portion;.of.the .floor may-be assumed as acting in flexure in com- <br />bination with the beam. <br />The width of the slab so acting in flexure is to be governed by the sheariizg <br />resistance between slab and beam,.but limit,ed to awidth equal to one-third (1/3) of <br />the span lengtH of the beams betvteen supports and also limited to a span length ?6f <br />three-fourths:(.3/4) of the,distance from.center, to center between beams. <br />No part of the slab sY!all be coneidered as a portion of the rib, unless the <br />slab and. rib a,re cast at the same time. __ . ..... . , <br />Where reinforced concrete girders support reinforced concrete beams, the p or- <br />tion of the floor slab actin; as flari.ge to the girder must be reinforced ?rith rods <br />near the top, at right angles to the girder to enable it to transmit local loads dir- <br />ectly to the girder and no# through the beams. <br />Sec.130. tAlh]B-STRESSES. VJhere the diagonal tension exceeds 4-0 .1bs. per sq. in. <br />additional vaeb reinforcement of approved d.esign shall be usedo <br />Stirraps shall not be placed further apart then te+ro-thirds. (2/3) °'d'! i-L tliey <br />are corisidered as adding to the shearing resistance, In no case'shall the'shear ex- <br />ceed 125 lbs.. per sq. in. lVhen reinforcement is used to increase the uriit shear, the <br />proportion of the nnit sheax taken by.the concrete sha.ll not exceed 40 lbso per sqo <br />ins and the reingorcoment.shall be sufficient to take the rema.inder. '.If.:unattached <br />stirrups are used they sha.ll pass under the main reinforcing bars.. _ ;. . <br />There shall be sufficient-, anchora,;e to develop the stirrups: above tYie neutral <br />axis of the bdams cuithout exceedi.ng:the„bond stresses specified..,If the stirru.ps are <br />attached to the reinforcing bar,s?-thp; conncecion rmzst -be sufficient 'to develop 'the el- <br />astic limit of the steel without causing^slipping along_the main.bars. -,, If the reinforcing rods,are.bent'to approximately 45 degrees and are spaced <br />no further apart than "d" .or:if_-.the.bars are bent at the one-fourth`(?) points, they <br />may be figured a's shear meinbers in providing- for the:.excess shear over 40 lbs per <br />sq. in. If a beam is required:to carry_a series of concentrated loadsthe bending <br />of the reiilfox•cing bars should be gove.rned-accordingly..., y . . _