Laserfiche WebLink
Notation 90d" is the effective depth or distande fror.i the compressive face <br />to the center' of.the ste,el in inches. <br />Sece131. SQUARTE AND F,.ECTANGULAR SLABS, For square slabs ztritYi two caay re- <br />inforcements, the bending moment at the center of the slab -shall be not less <br />°than 20. WT,2 for intermediate spans, and 18 WI,2 for the end spans. <br />The moment eYer supporty shall be no-t less than 30 11FI,2 and the sum o f the <br />moments over one support and at the center of the span sha11 be -talcen not less <br />than 10 V'dL2 in which above Formula' "tiU" is the load per liileal foot and "Lr" the <br />lergth of spana For square or rectangular slaus the distribution of the loads- in the twro <br />directions, sha11 be inversely as the cubes oi the i;wo dimensionso <br />Concrete beams and girders ynist be so- designed that the total comPressive <br />stress to which:' the membex'may be subjected'will cornpare with the total stress <br />taken by the steel reinforcementa Should the available area of section above <br />the neutral axis be insufficients,the area, of seCtien of the member shall be in- <br />creased or a sufficient amount-of compression steel be provided to insure an ef- <br />ficient resisting moment. ' Seca132. TILE AND JOIST CONSTPUCTIONm 11l'nere reinforced concrete joist, <br />with intermediate rovus of hollovr tile are erttployed, the stresses shall be cal.- <br />culated by the,same fbrmulas provided for beams and girders. <br />Secv133o Should the type of construction knovm as Flat'Slab, Ciraular <br />Plate, Yushroom System, etce9 be employed the plans and specifications diall <br />bear the signed approval of sorne recognized er_gineer of authority on the design <br />of reinforced concrete constrizctiono <br />Secalv4. REINFORCM) COPaCRE.'''iE COLU??I?TS. Reinforced concrete colwvns shall <br />not exceed in length 15 times the least sid.e or diameter, and where such columns <br />ea.ceed 12 titnes the least diamete'r or side, -tYle allowable conipression of the con- <br />crete shall ae taken as 500 pounds multiplied by the least side or diameter of <br />tlze coltiurm in inches and divided by the unsupported length in feeta For eolumns subjeet to eccentric loading or bending of an intermedia,te a- <br />mount, the above stre9s shall be reduced at least 20 per cent. <br />171zen the bor_c%ing stresses in a column can be defir_itely determined, the <br />combined be-n_ding and direct stress slzall not exeeed 500 pounds per sq. in. <br />Colurnns erith lorigitudinal rods shall have at least 1 sq. in. of steel in <br />the total axea., a.nd not less than 4 rods; and rods shall not be.used of a 1 ess <br />diameter than z inch. The area.oi the longitudinal rods sha11 not be 1 ess than <br />? of one per eent (1 per cent)- of the required cross section,area of the columzz <br />and shall not exceed 4 per cen-t oi the effective cross seeti,onal area of the co1- <br />umn. The longitudinal rods must be-tied together to resist outcrard flext.lre at <br />intiervals'not greater than'tne lea.st vridth or diameter of column. <br />The steel hoops shall not be less than -L inch diameter 3n dEpaced not more <br />than 12 incnes aparto <br />B??( <br />Sec.ke5. CONCRETL+'' COLUh?N F'OOTINGS., Plain Footingso The, area oi the 1ower <br />cottrse of concreie footirk,s snall be governed by t11e available resistance of the <br />?soil upon which they are to oe placed. Single course footings shqll be not less <br />than sixteen (16) tnches thick. LVhere more than one eourse is required- no course