Laserfiche WebLink
' ? ... _J <br />ter of bore hole is below.,one--fifth. (1/5) of • its, depth..from the top, nor at a <br />.' point .be?rond`three (3) tirries it,s depth,from the ends.: Cuts,.or center.s of -bore <br />holes shall never be of more than two (2). inches below.the, top; and 'if.,the depth <br />of a two inch or less cut or bore hole.i s required to be ma.cle, and if sucli cut <br />. exceeds one-fifth (1/5) the depth of the_joist, suclz joist shall be made of the <br />riext 'size deeper, or the.:"de'sign of the pi'ping or wiring sliall be changed.. Un- <br />" der no "`circiuristances, ,except for constru:ctiae :framing, 'shall. a joist or beam be <br />'cut or channeled out vertically, nor shall a stud;.post or pla:te in a bearing <br />partition be cut into in arr.4yy direction eicept that plates may? be cut to a depth <br />of one-third (1/3) t;heir width,. but not exceeding one-quarter (4 ) oi their area <br />between supporting stids for the passa,ge 'o:f water and gas p ipe a.nd electric wires <br />or tubirig, and that studs may be bored near their centers for electric knob and <br />tube" work 'if the diameter ai such tubes does not 'exceed orie-fi=t}i (1lb ) of the <br />deptlz: 'of such -studs and are.. spaced, no_ nearer tnan twelve (12), 'in.ches on. centers. <br />Sec.155. ANCHORS. Fach tier of beams shall be ancilored to' the side, f'ront, <br />rear, or ps,rty_.tivrzll,s at intervals of not,rnore tllan eight (8) feet apart, vrith <br />good, strong, wrought iron ancliors. The-ends of bearns resting' izpon girders shall <br />.. . be; "?buttea together eild to end, and strappecl'with wrought iron stra.ps of the same <br />- size and distance apart, and in 'the same beam as'the wa.ll anchors,,, or' they may <br />lap 'each other at least twelde (12) inches' and be ?,,ell spiked or boltea.'together <br />Frhere lapped, or spiked to their bearings and ;studs as in balloon 'framing. _ <br />lYhere beams are,. supported by,girders, the*girders, shall be anchored to_ the walls <br />and fastened to" each other by suitable strapsl.- <br />Evex?y pier or wall, front or rear, shall be vrell ancliored to tiie Ueams <br />with the same smze anchors as are required for the side walls, v,rhich'anchors <br />shall in all cases be long enough to hook.oeer the second joist, but no anchor <br />shall cut into a beam or.joist vrithin four (4) 'feet of_its center.' . <br />Seco156o S'i'tTD PARTITIONS. No- stud or frame'partion shall be used as a <br />Division IVall, betvieen different apaxtrlents as in.the case of tctso o-r four fam- <br />ily houses, tivhich must in all cases be of brick or otner fireproof material <br />..suitable for the purpose and capable of carrying the load which may be imposed <br />. upon theiri: , : • - '. . <br />Nv s tud 'in a bearing' partition iiiall shall be less than twoA2) inches b.y <br />four (4) inches spaced not ever sixteen (16)inches ori ceriters. -No wooden stud <br />partition.exedpt in buildings not exceeding ttvo l2} stories'high shall pass? <br />' through from floor to_floor, and-hereafter all fore'and-aft-and a11 bearing par- <br />titioiis; and a11 stud partitions'twhich arre 'd.irectly ove'r each other, shall run <br />. throut;h to the_wooden.floor beams or joi,sts and rest upon the plate, beam or <br />girders below, 'arid siiall have the studdirg filled in. solid betvreen• the uprights <br />to the. depth . of tne floor beams with suitable incoinbustible m.terials, single <br />"dtivellirigs, designed,to be°occupied by'but one, (l) -family, alone exceptedo ' <br />'"- ATon-bearing stud p?.?rtition.s may,rest directly' on aplate : over double <br />joists or on the "rough floor at-righ.t angles to'the-joists, provided that a: <br />similar plate or 'cut-of.f'is placed ;au'the head or ceiling 1ine. ' " J . , . . ' . . ' . . . ,.. . . .- . _ . . . <br />All angles and corners of studs shall be.fr"a:ned solid, and no lathshall <br />extend through from room to room: ? ' ` ,.. . <br />Stud framing around all doors and windows-shall be doubled, and if neces- <br />sary in case of. openin.gs over five? feet _in ;width "to be properly trussed. <br />Sec.15% CHUTES AND PIPES IN STiTD PARTITIONS. ,A11 studs partitions con- <br />taining? plumbing, heatiizg or other pipes shall be"so framed and the;joists or <br />beams underneath so sgaced or blocked apart or triilvned, as to give proper'clea.r-