ance for the piping witllout cutting, as prescribed in Section 154 and all such
<br />piping passiizg through the floors shall be boxed in and fire s-Lopped between. joists
<br />to preveil'u the spread of firee.
<br />No chute which is bu"ilt to connact the bastment with the upper floors of
<br />any building, virether same is used fo-r the puspose of dumb waiter or clothew chute,
<br />sha.ll be built unless the same is properly p-ro'uecteci from ri.re and has proper self
<br />closing fire proof doors in basement. . '"
<br />' TITI,E X-PI,ASTERIIvG.
<br />Section.l58m QUALITY. The coat of plas'uering upon any Urall,*ceiling or
<br />colvmn shall not be regarded as part oT the thickness, and no plaster vrhich has
<br />plaster oi paris or liine as an ingred-ient wrill"Ue elassed as a fire or water resis-
<br />ting plaster. . Sec.159. TNSPECiIGTd. No pipirg or wiring shall be covered in by lathing,
<br />sheathing or.othercuise until the irispector has by examination'ascertained'that the
<br />building, partition, structure, pipiiig or «iring:hag oeen built in compliance with
<br />the provisions of this,Coae. `I'he inspector shall be notified by the owner or ris
<br />dul.,y authorized agenl;,. or by the contractor; for such, piping and wirin.g vnenever
<br />arW buildirig is ready for inspection. And no piping or wiiing sha.ll be covered in
<br />by lathing, plastering, sheathing or othei-erise, until inspection is made, and the
<br />inspector has issued a certificate to the effect tha.t the builaing, partition,
<br />sti-uci;ure, piping or tviring has been built in cornpliance ivith the provisions of
<br />this Code.
<br />. Sec.160. PLkS'I'ER VENEER.-. Outsicle plasteririg. on ivood, or metal lath attached
<br />to wooden fraxnes or furring sYia i-1 be classed'as a veneerecl bJooden frarne and the
<br />use of such veneier, in bafs 'or gables shall be limited to dvrellings.
<br />TITLE.XI??CHIRNEYS, FLUES AND, STACKS
<br />Section 161. IRTrEBER. No 'person -snall build: or cause to be'tililt any chimney
<br />or stack to be used to carry off smoke of any steam boiler, «rhetrer the same be
<br />used either for the fZriiishing. oi hea,t or power, except chimneys oi private resi-
<br />dences, unless sucn, chirnney or stack be buil-t of iron; brick, or stone, and shall
<br />have a height of not less thaii 55 'feet from grade. Each dtvelling; terieinent or a-
<br />partment, stable or ?garage, ` oi , ar?y room in v?hich cooking or heating is done b.y coal,
<br />vrood, or gas, shallhave at least -one chirnney, built as Y?ereinafter described.
<br />' Sec.162. COTdSTRUCTI0IU 'GF CHIhSrEYS AND FZU"ES. Chimrieys shall be built of
<br />brick, stone or sirnilar fireprooi materials,. and in no .case snall a chimney rest
<br />upon a flooriiig of wood-or timber construction. Ere:cy chimney not_,forming part of
<br />a cua11, s1:a11 restupon the . ground or other sufiicient fireproof foundation. Brick-
<br />work or all flues,.ti4ithout reference to the purpose, for,Lrhich they nlay be intended
<br />must be laid ivith solid joints, thoroughlv filleci rrith .mortar or grouted and the
<br />, joints struck flush. on the inside and plastered on ttie..outside Where tYie_ypass
<br />through floors and partitions and betweeri the ceilin.g joists arid rafters and rio o-
<br />pening between.the joists shall be made or left for ar?,y gurpose. All smoke flues
<br />to be lined with fire cla.y linings' throughout.
<br />V7oodeil floor beams, studs and other wooclwp rk. niust be franied around the flues
<br />at each and eve?-y story and, be not less than one' ! 1) ";i:nch; ekcept triwmers, which
<br />shall be two (2) inches distant therefron. -
<br />. Holloi•r tile shall not be,-used in any rnanner in the construction of ar?,y chim-
<br />. neys. : . . . .
|