Laserfiche WebLink
§ 1593.71 <br />DWELLING HOUSE CODE <br />1593.71 Materials for vents and venting. <br />Vent piping above ground shall be of cast <br />iron, galvanized wrought iron, galvanized <br />steel and ferrous alloys, lead, brass or copper <br />pipe, copper tube or other approved mate- <br />rials. The pipe and fittings for each type of <br />pipe, including malleable fittings, shall com- <br />ply with the applicable specifications listed in <br />Table 93A. Vent piping placed underground <br />shall be cast-iron soil pipe. Other materials <br />may be used for underground vents when <br />first approved and installed as directed by <br />the Building Official. Threaded joints ap- <br />proved for use underground shall be coated <br />and wrapped after installation and test. <br />1593.72 Protectflon of trap seal. <br />The protection of trap seals from siphonage <br />or back pressure shall be accomplished by <br />the appropriate use of soil or waste stacks, <br />vents, revents, back vents, loop, circuit or <br />continuous vents or combinations thereof <br />installed in accordance with the require- <br />ments of this Chapter 93. The system of <br />vent piping shall permit the admission or <br />emission of air so that under normal and in- <br />tended use the seal of any fixture trap shall <br />not be subjected to a pressure differential <br />of more than one (1") inch of water. <br />1593.73 Vent stacks. <br />A vent stack or main vent shall be in- <br />stalled with a soil or waste stack whenever <br />back vents, relief vents or other branch <br />vents are required in two or more branch in- <br />tervals. The vent stack shall terminate in- <br />dependently above the roof of the building <br />or shall be connected with the extension of <br />the soil or waste stack (stack vent) at least <br />6 inches above the flood level rim of the <br />highest fixture. Every building in which <br />plumbing is installed shall have at least one <br />main stack which shall run undiminished in <br />size and as directly as possible from the <br />building drain through to the open air above <br />the roof. <br />.. <br />1593.74 Vent terminals. <br />(a) Roof extension. Extension of vent <br />pipes through a roof shall be terminated at <br />least 1 foot above it. Where a roof is to be <br />used also for any purpose other than weather <br />protection, the vent extension shall be run at <br />least 6 feet above the roof. Each vent ter- <br />minal shall be made watertight with the roof <br />by proper flashing. <br />(b) Attachments. Vent terminals shall <br />not be used for the purpose of attaching or <br />anchoring flagpoles, television aerials or <br />similar devices. . <br />112 <br />(c) Location of vent terminals. No vent <br />terminal from a drainage system shall be di- <br />rectly beneath any door, window or other <br />ventilating opening of the building or an <br />adjacent building nor shall any such vent <br />terminal be within 12 feet horizontally of <br />-such an opening unless it is at least 3 feet <br />above the top of such opening. Vent ter- <br />minals shall not: terminate under the over- <br />hang of the building: No soil, waste or vent <br />pipe extension of any new building shall be <br />run or placed on the outside of a wall but <br />shall be carried up inside the. building. <br />(d) Extension through wall. Vent ter- <br />minals extending through a wall shall be at <br />least 12 feet horizontally from any building <br />line, shall be turned to provide an opening <br />downward and shall be effectively screened, <br />all subject to the specific approval of the <br />Building Official. <br />(e) Provision against frost closure. Vent <br />extensions and vent terminals extending <br />through a roof or wall shall be not less than <br />the diameter of the vent stack or stack vent <br />which they serve but in no case less than 4 <br />inches in diameter. A change in diameter, <br />if required, shall be made at least 1 foot <br />below the roof construction or, for exten- <br />sionsthrough awall, at least 1 foot inside the <br />inner face of the wall. <br />1593.75 Vent-pipe slopes and connections. <br />(a) Slopes, All vent and branch-vent <br />pipes shall be free from drops or sags and <br />shall be sloped and connected so as to drip <br />back to the soil or waste pipe or vent stack <br />by gravity. <br />(b) Soil or waste pipe. Where vent pipes <br />connect to a horizontal soil or waste pipe, <br />the vent shall be taken off above the center <br />line of the soil or waste pipe and, wherever <br />possible,. shall rise vertically, or at an angle <br />not less than 45° to the horizontal, to a point <br />at least 6 inches above the flood-level rim of <br />the fixture it is venting before offsetting <br />horizontally.. or, before .,connecting ,to, the <br />branch vent, except as may be otherwise <br />approved by the Building Official. Side-inlet <br />closet bends, with center line of side tapping <br />above the horizontal center line of the bend, <br />are permitted only incases where the fixture <br />connected thereto is vented and in no case <br />shall the inlet be used to vent a bathroom <br />group without being washed by a fixture. <br />(c) Connection to vent stack. A connec- <br />tion between a vent pipe and a vent stack <br />shall be at least"6"inches above the flood- <br />level rim of the highest fixture served by <br />the vent pipe. Horizontal vent pipes form- <br /> <br /> <br />• ~ <br />13 Registration, Licensing and Certificates <br />§ 1515.13 <br />tion, each Board of Examiners shall be ap- <br />pointed by the Mayor and shall consist of <br />three members, at least two of whom shall <br />have been registered, licensed or certified as <br />qualified in that particular field of building <br />construction. The term of office and com- <br />pensation for the members of each Board of <br />Examiners shall be established by Council. <br />1515.07 Removal of appointed members of <br />Boards of Examiners. <br />Any appointed member of a Board of Ex- <br />aminers may be removed by the Mayor on <br />proof of official misconduct, or of negligence <br />in official duties, or of conduct in any man- <br />ner connected with the official duties which <br />tends to discredit his office, or of mental or <br />physical disability to perform his duties; but <br />before removal he shall receive a copy of <br />the charges, and shall be entitled to a hear- <br />ing before the Mayor in person or by coun- <br />sel, and the action of the Mayor shall be <br />final. <br />1515.08 Secretary of Boards of Examiners. <br />The Mayor shall appoint a secretary for <br />the Boards of Examiners. Said secretary <br />shall receive such compensation as fixed by <br />the Council and shall keep a record of the <br />activities and actions of the Boards of Ex- <br />aminers and their determinations, shall re- <br />ceive and file applications for licenses, notify <br />applicants of the time and place of examina- <br />tions and the results thereof, file examina- <br />tion questions and answers and shall per- <br />form such other duties as are consistent with <br />those prescribed in this paragraph and as <br />directed by the Boards. <br />1515.09 Certification by Board of Ex• <br />aminers. <br />Whenever a Board of Examiners has as- <br />certained that an applicant has the required <br />qualifications and competency, it shall so <br />certify to the Building Official, wlio shall <br />thereupon issue a license in conformity with <br />the certificate received therefor. <br />1515.10 Age and character of registrants, <br />licensees, and holders of certificates <br />of qualification. <br />No applicant shall be registered", licensed, <br />or issued a certificate of qualification under <br />the provisions of this Dwelling House Code, <br />unless such applicant shall be: <br />i. Not less than 21 years of age, and <br />ii. Able to read and write the English lan- <br />guage, and <br />iii. Of good moral character.' ~.' <br />1515.11 Revocation and suspension of regis- <br />tration, licenses, and certificates of <br />qualification. <br />A certificate of registration, license or cer- <br />tificate, of qualification may be revoked or <br />may be suspended by the Building Official <br />for a prescribed period not exceeding six <br />months, whenever he has determined that <br />the holder thereof: <br />i.. Has not performed the duties required <br />of him by this Dwelling House Code or by <br />the rules or regulations of the Building <br />Official or the Board of Building Code ,Ap- <br />peals; or <br />ii. Has been lax, incompetent, negligent, <br />or derelict in the prescribed performance <br />or in the performance of work or furnishing <br />of services authorized by such certificate; or <br />iii. Whenever the holder thereof has vio- <br />lated or participated in the violation of any <br />provision of this Dwelling House Code. <br />Provided, however, that on request of the <br />holder of a certificate or license, a public <br />hearing shall be held by the Building Offi- <br />cial before such certificate or license is re- <br />voked and provided further that an appeal <br />may be taken as provided in Section 1515.15. <br />The holder of a suspended certificate or <br />license shall not do any work authorized <br />by such certificate or license, except work <br />necessary to correct a violation of this Dwell- <br />ing House Code specified in the notice of <br />suspension, until notice of reinstatement has <br />been given by the Building Official or the <br />period of suspension has expired. . <br />1515.12 Fees for registration, licensing, and <br />certificate of qualification. <br />(a) Fees for certificates of registration, <br />licenses and certificates of qualification and <br />renewals thereof shall be established by the <br />Council and shall be paid at the office of the <br />Building Official. - <br />(b) Fees shall be payable upon accept- <br />ance of the application for a license or cer- <br />tificate. An application shall not be deemed <br />accepted until the authority having jurisdic- <br />tion has examined such application and de- <br />termined therefrom that the applicant is <br />qualified under Section 1515,10 and possesses <br />the experience, training, and education req- <br />uisite for the license or certificate in ques- <br />tion. <br />1515.13 Expiration and renewal of licenses <br />and certificates. <br />When payment of a renewal fee :is_pre- <br />scribed, .licenses and certificates: of: registra- <br />tion and qualification and::renewals~:thereof <br />