§ 1591.43 DWELLING HOUSE CODE 94
<br />of this Section shall not apply when auto-
<br />matically controlled oil or gas-fired furnaces
<br />are installed and the combustion rate is ad-
<br />justed so that the heat input, irrespective of
<br />furnace size, cannot exceed the heat loss
<br />of the building with outdoor temperature of
<br />-5 F and wind velocity of 15 mph, provided
<br />the warm air pipe or duct areas and the free
<br />areas of registers and grilles are adequate to
<br />convey and discharge the warm air required
<br />to heat the building.
<br />(d) Exception for existing buildings. The
<br />provisions of (a) and (b) of this Section
<br />shall not apply when automatically con-
<br />trolled furnaces are installed in an existing
<br />building and it is determined by the Board
<br />of Building Code Appeals that strict enforce-
<br />ment of the provisions of (a) and (b) of this
<br />Section would result in undue hardship, pro-
<br />vided that the heat input into the furnace
<br />is. controlled by a temperature limit control
<br />and a room thermostat so that the bonnet
<br />temperature will not exceed 200 F, and pro-
<br />vided further that the warm air pipe or duct'
<br />areas and the areas of registers and grilles
<br />are adequate to convey and discharge the
<br />heat delivered by the furnace when so con-
<br />trolled.
<br />1591.43 Warm air supply ducts and connec-
<br />tions.
<br />(a) Warm air pipe and duct requirements.
<br />All warm air distributing pipes or ducts
<br />from the furnace or heater shall be con-
<br />structed entirely of noncombustible material
<br />equivalent in structural strength and dura-
<br />bility to the following:
<br /> WARM AIR DISTRIBUTING PIPES
<br />Diameter, Minimum Minimum Thickness Minimum Thickness
<br />Inches Weight of Tin of Galvanized Iron of -Aluminum
<br />Less than 12 IC (107 lb,) 30 U. S. Gage 26 B. & S. Gage
<br />12 or more IX (135 lb.) 28 U. S, Gage 26 B. & S. Gage
<br /> WARM AIR DISTRIBUTING DUCTS
<br /> Minimum Thickness Minimum Thickness
<br />Width, Inches o f Galvanized Iron o f Aluminum
<br />14 or less 28 U. S. Gage 26 B. & S. Gage
<br />over 14 to 36 26 U. S, Gage 24 B. & S. Gage
<br />over 36 24 U, S. Gage 22 B. & S. Gage
<br />(b) Warm air riser requirements. Warm tural strength and durability to the follow-
<br />air risers shall be constructed entirely of ing:
<br />noncombustible material equivalent in struc-
<br /> WARM AIR RISERS
<br />Width, Minimum Minimum Thickness Minimum Thickness
<br />Inches Weight of Tin of Galvanized Iron of Aluminum
<br />14 or less IC (107 lb.) 30 U. S: Gage 2G B. & S. Gage
<br />over 14 IX (135 lb,) 28 U. S. Gage 26 B. & S. Gage
<br />(c) Construction. All warm air supply
<br />pipes, ducts, fittings, and register boxes shall
<br />be secured in place and constructed so as not
<br />to obstruct air flow. Transition connections
<br />shall be used for runs connected to boots,
<br />Pipes and ducts shall be securely supported
<br />by metal hangers; straps, lugs, or brackets.
<br />No nails shall be driven through pipe or duct
<br />walls. ,
<br />(d) Joints and seams.- Joints and seams
<br />of pipes and ducts shall be securely fastened
<br />and made substantially air tight. Slip joints
<br />shall have a lap of at least 1~/z inches and
<br />shall be fastened and sealed in a manner
<br />approved by the Building Official.
<br />(e) Insulation. Warm air supply pipes or
<br />ducts which pass through any unheated
<br />space shall be insulated with a minimum of
<br />3-ply asbestos air-cell covering or its equiv-
<br />alent.
<br />(f) Linings. Linings used inside of pipes
<br />or ducts shall be fire-resistive.
<br />(g) In outside walls. Registers for warm
<br />air, and warm air pipes, stacks or fittings
<br />shall not be located in outside walls unless
<br />insulated on the cold side with a minimum
<br />of 1 inch asbestos air-cell covering or its
<br />equivalent.
<br />(h) Shutters and dampers. Warm air heat-
<br />ing systems, other than systems which are
<br />automatically fired with oil or gas and have
<br />approved temperature limit controls, shall
<br />have at. least one register or grille without
<br />a closeable shutter and the duct leading
<br />• 31
<br />National Standards
<br />fraction thereof of the total distance around
<br />the room, measured horizontally along the
<br />wall at the floor line. The receptacle out-
<br />lets shall be, insofar as practicable, spaced
<br />equal distances apart around the perimeter
<br />of such room. At least one receptacle out-
<br />let shall be installed for the connection of
<br />the laundry appliance. This receptacle shall
<br />be of a 3-pole type designed for grounding
<br />the appliance. A suitable approved ground
<br />conductor shall be extended from such re-
<br />ceptacle to a grounding connection. All re-
<br />ceptacle outlets installed on the outside face
<br />of a building, or in any manner outside the
<br />building, shall be of the 3-pole weatherproof
<br />type.
<br />(d} Paragraph 3202, entitled USE, of
<br />Article 320, shall be considered as amended
<br />and as amended shall read:
<br />"Open wiring on insulators shall not be
<br />used in basements, cellars, storage spaces,
<br />or in habitable rooms or in any location,
<br />not a concealed space, where the installa-
<br />§ 1521.15
<br />tion of open wiring on insulators would be
<br />hazardous."'
<br />(e) Paragraph 3342, entitled USE, of
<br />Article 334, shall be considered as amended
<br />by adding at the end thereof, the following:
<br />"Armored cable shall not be installed so
<br />as to be exposed where subject to mechan-
<br />ical injury. Exposed armored cable mounted
<br />on wall surfaces and within 4 feet of the
<br />floor level shall be, deemed to be subject to
<br />mechanical injury unless the conditions of
<br />installation are such that it is shielded from
<br />mechanical injury."
<br />(f) Paragraph 3441, entitled, USE, of
<br />Article 344, shall., be considered as amended
<br />and as amended shall read:
<br />"Underplaster extensions, installed as per-
<br />mitted by Sections 3441 to 3444 inclusive,
<br />may be used only for extensions of existing
<br />branch circuits, if laid on the face of ma-
<br />sonry or other material and buried in the
<br />plaster finish of ceilings or walls."
<br />1521.15 Standards of the American Standards Association: Prefix "Z."
<br />(Sponsored by American Gas Association)
<br />221.1-1948 Approval Requirements for Domestic Gas Ranges, with addenda
<br />
<br />221.2-1949 Z21.1a-1949.
<br />Listing Requirements on Gas Hose for Portable Gas Appliances.
<br />221.5-1940 Approval Requirements for. Clothes Dryers.
<br />R 1947 -
<br />Z21.6-1949 Approval Requirements for Domestic Gas-Fired Incinerators.
<br />221.8-1948 Requirements for Installation of Domestic Gas Conversion Burners.
<br />221.9-1948 Approval Requirements for Hot Plates and Laundry Stoves, with
<br /> addenda Z21.9a-1949.
<br />221.10-1950 Approval Requirements for Gas Water Heaters.
<br />221.11-1949 Approval Requirements for Gas-Fired Room Heaters, with Z21.11a.
<br />221.12-1937 Listing Requirements for Draft Hoods.
<br />R 1950
<br /> Approval Requirements for Central Heating Gas Appliances,
<br />221.13.1-1951 Volume I-Steam and Hot Water Boilers.
<br />221.132-1951 Volume II-Gravity and Forced Air Central Furnaces.
<br />221.13.3-1951 Volume III-Gravity and Fan Type Floor Furnaces.
<br />221.13.4-1951 Volume PJ-Gravity and Fan Type Vented Recessed Heaters.
<br />221.15-1944 Listing Requirements for Gas Valves, with addenda Z21.15a-1949.
<br />221.16-1951 Approval Requirements for Gas Unit Heaters.
<br />221.17-1948 Listing Requirements for Domestic Gas Conversion Burners.
<br />221.18-1934 Listing Requirements for Domestic Gas Appliance Pressure. Regu-
<br /> lators.
<br />221.19-1941 Approval Requirements for Refrigerators Using Gas Fuel.
<br />R 1950
<br />22120-1951 Listing Requirements for Automatic Pilots.
<br />221.21-1948 Listing Requirements for Automatic IUIain Gas-Control Valves,
<br />' 221.22-1935 Listing Requirements far Relief and Automatic Gas Shut-off Valves
<br />R 1950 for use on Water Heating Systems.
<br />221.23-1940 Listing Requirements for Gas Appliance Thermostats.
<br />221.24-1941 Listing Requirements for Semi-Rigid Gas Appliance Tubing and
<br />R 1947 Fittings.
<br />221.26-1941 Listing Requirements for Attachable Gas Water heating' Units.
<br />® ~
<br />R 1950