Laserfiche WebLink
§ 1591.43 DWELLING HOUSE CODE 94 <br />of this Section shall not apply when auto- <br />matically controlled oil or gas-fired furnaces <br />are installed and the combustion rate is ad- <br />justed so that the heat input, irrespective of <br />furnace size, cannot exceed the heat loss <br />of the building with outdoor temperature of <br />-5 F and wind velocity of 15 mph, provided <br />the warm air pipe or duct areas and the free <br />areas of registers and grilles are adequate to <br />convey and discharge the warm air required <br />to heat the building. <br />(d) Exception for existing buildings. The <br />provisions of (a) and (b) of this Section <br />shall not apply when automatically con- <br />trolled furnaces are installed in an existing <br />building and it is determined by the Board <br />of Building Code Appeals that strict enforce- <br />ment of the provisions of (a) and (b) of this <br />Section would result in undue hardship, pro- <br />vided that the heat input into the furnace <br />is. controlled by a temperature limit control <br />and a room thermostat so that the bonnet <br />temperature will not exceed 200 F, and pro- <br />vided further that the warm air pipe or duct' <br />areas and the areas of registers and grilles <br />are adequate to convey and discharge the <br />heat delivered by the furnace when so con- <br />trolled. <br />1591.43 Warm air supply ducts and connec- <br />tions. <br />(a) Warm air pipe and duct requirements. <br />All warm air distributing pipes or ducts <br />from the furnace or heater shall be con- <br />structed entirely of noncombustible material <br />equivalent in structural strength and dura- <br />bility to the following: <br /> WARM AIR DISTRIBUTING PIPES <br />Diameter, Minimum Minimum Thickness Minimum Thickness <br />Inches Weight of Tin of Galvanized Iron of -Aluminum <br />Less than 12 IC (107 lb,) 30 U. S. Gage 26 B. & S. Gage <br />12 or more IX (135 lb.) 28 U. S, Gage 26 B. & S. Gage <br /> WARM AIR DISTRIBUTING DUCTS <br /> Minimum Thickness Minimum Thickness <br />Width, Inches o f Galvanized Iron o f Aluminum <br />14 or less 28 U. S. Gage 26 B. & S. Gage <br />over 14 to 36 26 U. S, Gage 24 B. & S. Gage <br />over 36 24 U, S. Gage 22 B. & S. Gage <br />(b) Warm air riser requirements. Warm tural strength and durability to the follow- <br />air risers shall be constructed entirely of ing: <br />noncombustible material equivalent in struc- <br /> WARM AIR RISERS <br />Width, Minimum Minimum Thickness Minimum Thickness <br />Inches Weight of Tin of Galvanized Iron of Aluminum <br />14 or less IC (107 lb.) 30 U. S: Gage 2G B. & S. Gage <br />over 14 IX (135 lb,) 28 U. S. Gage 26 B. & S. Gage <br />(c) Construction. All warm air supply <br />pipes, ducts, fittings, and register boxes shall <br />be secured in place and constructed so as not <br />to obstruct air flow. Transition connections <br />shall be used for runs connected to boots, <br />Pipes and ducts shall be securely supported <br />by metal hangers; straps, lugs, or brackets. <br />No nails shall be driven through pipe or duct <br />walls. , <br />(d) Joints and seams.- Joints and seams <br />of pipes and ducts shall be securely fastened <br />and made substantially air tight. Slip joints <br />shall have a lap of at least 1~/z inches and <br />shall be fastened and sealed in a manner <br />approved by the Building Official. <br />(e) Insulation. Warm air supply pipes or <br />ducts which pass through any unheated <br />space shall be insulated with a minimum of <br />3-ply asbestos air-cell covering or its equiv- <br />alent. <br />(f) Linings. Linings used inside of pipes <br />or ducts shall be fire-resistive. <br />(g) In outside walls. Registers for warm <br />air, and warm air pipes, stacks or fittings <br />shall not be located in outside walls unless <br />insulated on the cold side with a minimum <br />of 1 inch asbestos air-cell covering or its <br />equivalent. <br />(h) Shutters and dampers. Warm air heat- <br />ing systems, other than systems which are <br />automatically fired with oil or gas and have <br />approved temperature limit controls, shall <br />have at. least one register or grille without <br />a closeable shutter and the duct leading <br />• 31 <br />National Standards <br />fraction thereof of the total distance around <br />the room, measured horizontally along the <br />wall at the floor line. The receptacle out- <br />lets shall be, insofar as practicable, spaced <br />equal distances apart around the perimeter <br />of such room. At least one receptacle out- <br />let shall be installed for the connection of <br />the laundry appliance. This receptacle shall <br />be of a 3-pole type designed for grounding <br />the appliance. A suitable approved ground <br />conductor shall be extended from such re- <br />ceptacle to a grounding connection. All re- <br />ceptacle outlets installed on the outside face <br />of a building, or in any manner outside the <br />building, shall be of the 3-pole weatherproof <br />type. <br />(d} Paragraph 3202, entitled USE, of <br />Article 320, shall be considered as amended <br />and as amended shall read: <br />"Open wiring on insulators shall not be <br />used in basements, cellars, storage spaces, <br />or in habitable rooms or in any location, <br />not a concealed space, where the installa- <br />§ 1521.15 <br />tion of open wiring on insulators would be <br />hazardous."' <br />(e) Paragraph 3342, entitled USE, of <br />Article 334, shall be considered as amended <br />by adding at the end thereof, the following: <br />"Armored cable shall not be installed so <br />as to be exposed where subject to mechan- <br />ical injury. Exposed armored cable mounted <br />on wall surfaces and within 4 feet of the <br />floor level shall be, deemed to be subject to <br />mechanical injury unless the conditions of <br />installation are such that it is shielded from <br />mechanical injury." <br />(f) Paragraph 3441, entitled, USE, of <br />Article 344, shall., be considered as amended <br />and as amended shall read: <br />"Underplaster extensions, installed as per- <br />mitted by Sections 3441 to 3444 inclusive, <br />may be used only for extensions of existing <br />branch circuits, if laid on the face of ma- <br />sonry or other material and buried in the <br />plaster finish of ceilings or walls." <br />1521.15 Standards of the American Standards Association: Prefix "Z." <br />(Sponsored by American Gas Association) <br />221.1-1948 Approval Requirements for Domestic Gas Ranges, with addenda <br /> <br />221.2-1949 Z21.1a-1949. <br />Listing Requirements on Gas Hose for Portable Gas Appliances. <br />221.5-1940 Approval Requirements for. Clothes Dryers. <br />R 1947 - <br />Z21.6-1949 Approval Requirements for Domestic Gas-Fired Incinerators. <br />221.8-1948 Requirements for Installation of Domestic Gas Conversion Burners. <br />221.9-1948 Approval Requirements for Hot Plates and Laundry Stoves, with <br /> addenda Z21.9a-1949. <br />221.10-1950 Approval Requirements for Gas Water Heaters. <br />221.11-1949 Approval Requirements for Gas-Fired Room Heaters, with Z21.11a. <br />221.12-1937 Listing Requirements for Draft Hoods. <br />R 1950 <br /> Approval Requirements for Central Heating Gas Appliances, <br />221.13.1-1951 Volume I-Steam and Hot Water Boilers. <br />221.132-1951 Volume II-Gravity and Forced Air Central Furnaces. <br />221.13.3-1951 Volume III-Gravity and Fan Type Floor Furnaces. <br />221.13.4-1951 Volume PJ-Gravity and Fan Type Vented Recessed Heaters. <br />221.15-1944 Listing Requirements for Gas Valves, with addenda Z21.15a-1949. <br />221.16-1951 Approval Requirements for Gas Unit Heaters. <br />221.17-1948 Listing Requirements for Domestic Gas Conversion Burners. <br />221.18-1934 Listing Requirements for Domestic Gas Appliance Pressure. Regu- <br /> lators. <br />221.19-1941 Approval Requirements for Refrigerators Using Gas Fuel. <br />R 1950 <br />22120-1951 Listing Requirements for Automatic Pilots. <br />221.21-1948 Listing Requirements for Automatic IUIain Gas-Control Valves, <br />' 221.22-1935 Listing Requirements far Relief and Automatic Gas Shut-off Valves <br />R 1950 for use on Water Heating Systems. <br />221.23-1940 Listing Requirements for Gas Appliance Thermostats. <br />221.24-1941 Listing Requirements for Semi-Rigid Gas Appliance Tubing and <br />R 1947 Fittings. <br />221.26-1941 Listing Requirements for Attachable Gas Water heating' Units. <br />® ~ <br />R 1950 <br />