My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1988 050 Resolution
DOcument-Host
>
Mayfield Village
>
Ordinances Resolutions
>
1988 Resolutions
>
1988 050 Resolution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 3:54:03 PM
Creation date
8/8/2018 5:28:13 AM
Metadata
Fields
Template:
Legislation-Meeting Minutes
Document Type
Resolution
Number
050
Date
10/17/1988
Year
1988
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Mr. Gus Amendola, <br />PROPOSED PROGRESSIVE OFFICE PARK <br />September 12, 1988 <br />Page Two <br />8) 6" curbs to be concrete; <br />9) Buffer on Progressive Drive pavement appears to be <br />approximately sixty-five (65') feet for a short distance <br />The Village Engineer began reviewing the Preliminary Site Plan <br />which shows the proposed existing topo, utilities and proposed <br />final grades and has the following comments: <br />A) Show existing sanitary sewer and easement; <br />B) Plan states that pipe sizes are preliminary. <br />No Drainage Map or Drainage Calculations were submitted. <br />Some of the drainage appears to be diverted to another <br />drainage shed. Show storm connections to the proposed <br />buildings; <br />C) This Site Plan shows an intrusion into the 90' buffer area <br />of an 8" sanitary sewer; <br />D) The final grades in the buffer area indicate that a <br />significant area of existing trees will be removed; <br />E) Show final grade of buildings, the perimeter road, <br />critical sidewalk areas, elevations at outdoor steps and <br />balance of parking lots; <br />F) Is the mass grading of the south lot that is landbacked to <br />be done at this time? <br />G) The fire hydrants on the office should be extended to the <br />east side of the perimeter road; <br />H) The line weights on the drawing make it difficult to <br />follow the design. The proposed road and parking lots are <br />as light or lighter than the existing topo; <br />I) Show proposed gas mains and underground OBT, CEI & Viacom; <br />J) Some parking lot grades are too steep and some parking <br />lot grades are too flat. <br />V y truly viours, la) ?? ? <br />cc: Mayor Fred Carmzn/ hen . ovanc$ek <br />Mr. Robert Schulte ? <br />S,TH: j-
The URL can be used to link to this page
Your browser does not support the video tag.