Laserfiche WebLink
/~T CFfAGRI[3 <br />Cf ~ RIVER <br />WATERSHED <br />PARTtdERS <br />1 Nfay 2016 <br />3. BMPs that failed to operate as designed or proved inadequate for a <br />particular location. <br />4. Where additional BMPs are needed that did not exist at the time of <br />inspection. <br />F. Corrective action required including any necessary changes to the SWP3 <br />and implementation dates. <br />(3) Discharge locations shall be inspected to determine whether erosion and <br />sediment control measures are effective in preventing significant impacts to the <br />receiving water resource or wetlands. <br />(4) Locations where vehicles enter or exit the site shall be inspected for evidence of <br />off-site vehicle tracking. <br />(5) The applicant shall maintain for three (3) years following final stabilization the <br />results of these inspections, the names and qualifications of personnel making the <br />inspections, the dates of inspections, major observations relating to the <br />implementation of the SWP3, a certification as to whether the facility is in <br />compliance with the SWP3, and information on any incidents ofnon-compliance <br />determined by these inspections. <br />(i) MAINTENANCE. The SWP3 shall be designed to minimize maintenance requirements. <br />All BMPs shall be maintained and repaired as needed to ensure continued performance of <br />their intended function until final stabilization. All sediment control practices must be <br />maintained in a functional condition until all up slope areas they control reach final <br />stabilization. The applicant shall provide a description of maintenance procedures <br />needed to ensure the continued performance of control practices and shall ensure a <br />responsible party and adequate funding to conduct this maintenance, all as determined by <br />the Village Engineer. <br />When inspections reveal the need for repair, replacement, or installation of erosion and <br />sediment control BMPs, the following procedures shall be followed: <br />(1) When BMPs require repair or maintenance. If an internal inspection reveals that <br />a BMP is in need of repair or maintenance, with the exception of a sediment- <br />settling pond, it must be repaired or maintained within three (3) days of the <br />inspection. Sediment settling ponds must be repaired or maintained within ten <br />(10) days of the inspection. <br />(2) When BMPs fail to provide their intended function. If an internal inspection <br />reveals that a BMP fails to perform its intended function as detailed in the SWP3 <br />and that another, more appropriate control practice is required, the SWP3 must be <br />amended and the new control practice must be installed within three (3) to ten <br />(10) days of the inspection as determined by the community engineer or site <br />inspector. <br />(3) When BMPs depicted on the SWP3 are not installed. If an internal inspection <br />reveals that a BMP has not been implemented in accordance with the schedule, <br />the control practice must be implemented within ten (10) days from the date of <br />the inspection. If the internal inspection reveals that the planned control practice <br />23 <br />