Laserfiche WebLink
flowers which will require maintenance to ensure they do not become weedy looking and Mr. <br />Phillips said that they have a maintenance plan which will be adjusted for the new landscape <br />plan. Mr. Malone said a local provider who specializes in wildflowers should be used to ensure <br />the native and exotic wild flowers are successful. Mr. Lasko thanked the applicant for doing the <br />research to ensure the landscaping plan was comprehensive, enhancing the immediate area and <br />the community as well. <br />Mr. Rerko questioned the pool mechanical room which would be visible from the west elevation <br />and Mr. Phillips said the room would have the masonry base and the walls would be EIFS <br />matching the building materials. Mr. Rerko questioned how the pool house, mechanical room, <br />passageway and building roofs would be drained. Mr. Phillips said the pool roof drains to the <br />mechanical rooftop that is flat angled and includes a French drainage system which directs the <br />water to a scupper that ties into the passageway downspouts. Mr. Rerko said the height of the <br />mechanical room is higher than the pool house roof and he is concerned that the EIFS will not <br />stand up to the moisture, therefore the parapet should be modified or another material then EIFS <br />used. Mr. Phillips said they would address the concern and submit a more detailed drawing. Mr. <br />Rerko asked what was proposed for the south property line which abuts residents and Mr. <br />Phillips said based on the 2007 plan a fence was installed and the grounds remain natural. <br />Mr. Mitchell said the wall signs are shown as 57" tall and only 4' is allowed so a 17" height <br />variance is needed as well as a variance for an additional wall sign as two are allowed and three <br />are shown. Ms. Wenger said the directional and ground sign are not actually on the property but <br />located on an easement and comply with height and area requirements. Mr. Lasko said the <br />remote ground and directional signs serve as a purpose to identify the property owner and guide <br />customers to the hotel location. Furthermore the non-conforming pole sign will be removed and <br />an aesthetically pleasing conforming monument sign installed. <br />Mr. Lasko moved, seconded by Mr. Bohlmann, to recommend the Board of Zoning <br />Appeals grant CMS09-07 LaQuinta Inn & Suites of 25105 Country Club Blvd the following <br />variances: 1. A variance for 1 additional ground sign, code allows 2 and 3 are shown. 2. A <br />1' 7" height variance for wall signs, code allows 4' and 5' 7" is shown. The <br />recommendation is based on the fact that the height and square footage of the wall signs <br />are being reduced and aesthetically fit the new design of the building; the motion was <br />unanimously approved 7-0. <br />Mr. Lasko moved, seconded by Mr. Malone, to approve the development plans for CM509- <br />07 LaQuinta Inn & Suites of 25105 Country Club Blvd with the following conditions: <br />1. Mr. Malone's landscaping recommendations are to be implemented as described above <br />and agreed upon by the applicant. <br />2. The pool house, mechanical room and passageway drainage connection concerns are to <br />be addressed following Mr. Rerko's suggestion. <br />Both the landscaping and building modifications are subject to the Planning Director's <br />approval; the motion was unanimously approved 7-0. <br />COMMUNICATIONS <br />0 Ordinance No. 2009-63 An ordinance creating new chapter 1153 (Wind Energy Conversion