My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002-032 Ordinance
Document-Host
>
City North Olmsted
>
Legislation
>
2002
>
2002-032 Ordinance
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2014 4:02:56 PM
Creation date
12/30/2013 9:16:22 AM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2002-032
Legislation Date
3/19/2002
Year
2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />?"n-.:.... <br />17 One Two and Three-Familv DwellinizCode 1305.04 <br />(16) <br />(17) <br />Sec 323-Protection Astainst Decay and Termites (Amended). The <br />follawing sentence is added to Sectian R-323. 1: The top row of concrete <br />block on the foundatian must be solid type block to prevent teimites from <br />infesting the buildiniz. <br />NONIINAL PANEL THICKNESS column to any thickness less than 7/16 <br />of an inch. <br />(18) Sec 505 Concrete Ftoars (On Ground) (Amended). 505.1 neral: <br />Conerete slab-on-ground floors shall be constructed in accordance with <br />Figure No. 403 .1 a. The specified compressive strength of cancrete at 28 <br />aays shall be not less than 2,500 pounds per square inch except where <br />wea.ther exposure requires greater strength and air-entrained concrete, as <br />set forth in Table No. 402.2. <br />Slabs shall be constructed with control joints having a depth of at least <br />one-fourth the slab thickness, and joints shall be spaced at intervats nat <br />more than 30 feet in each direction and slabs not rectangular in shape shall <br />have comrol joints across the slab at points of offset if offset exceeds 10 <br />feet. <br />Sec. 5052.2 Base: Eliminate "crushed blast-furnace slag passing a 2-inch <br />(S l mrn) sieve" as an option. <br />EXCEPTION: Deleted <br />(19) Sec 901.3 Roofiniz coverina materials. (Amended) Add the sentence: <br />Asphalt or fiberglass shingles shall be a minimum 20 year warranty and <br />Class C rating. <br />(20) Sec 1901.1 Materials (Addedl. and/or in conformity to SMACNA <br />standards and manufaetnrer's specifications. <br />(21) Sec 1902.5 Return air ducts. (Addedl. Turning vanes shall be installed in <br />dact elbows going to electronic air cleaners. <br />(ZZ) Sec B-103-Req.uuemems (Amended). NOW APPENDIX B <br />B-103.1 Outdoor swimming pool: An outdoor swimming poal, including <br />an in-ground, above-gound or on-ground pool, shall be provided with a <br />barrier which shall comply with the following: <br />A. The tap of the barrier shall be at a height above grade measured on <br />the side of the barrier which faces away from the swimming pool <br />consistent with the requirements expressed in the Zoning Code of <br />the City. The maximum vertical clearance between grade and the <br />bottom of the barrier shall be 2 inches measured on the side af the <br />barrier which faces away from the swimming pool. Where the top <br />of the pool structure is abave grade, such as an above-ground pool, <br />the barrier may be at ground level, such as the pool stiucture, or <br />mountei on top of the pool structure. Where the barrier is mounted <br />on top of the paol structure, the maximum vertical clearance <br />between the top of the pool structure and the bottom of the bazrier <br />shall be 4 inches, which in any event shall be consistent with the <br />provisions of the Zoning Cade of the City. <br />B. Openings in the barrier shall not allow passage of a 4-inch <br />diameter sphere. <br />
The URL can be used to link to this page
Your browser does not support the video tag.