<br />210-53 Outlets Required. <br />Number of outlets required on general lighting and small <br />appliance branch circuits of dwelling occupancies: <br />No more than four duplex receptacle outlets per circuit <br />of #12 Wire A.W.G. shall be installed on the required <br />appliance branch circuits, and not more than ten duplex <br />outlet per circuit #14 wire, A.W.G. shall be installed <br />on the required general lighting branch circuits. <br />210-71. Wall Switches. <br />At least one outlet controlled by a wall switch shall be <br />provided for each habitable room, kitchen, toiletroom <br />and bathroom. A lighting outlet shall be provided at <br />laundry trays, boilers, furnaces andother central <br />heating devices. Three way switches shall be provided <br />for all stairways to control lighting outlets <br />illuminating such stairways. <br />210-73. Aluminum Conductors. <br />Aluminum conductors shall not be smaller than A.W.G. #6. <br />(Ord. 75-110. Passed 8-5-75.) <br />SECTION 2: That this Ordinance shall take effect and be in force at <br />the earliest date permitted by Article IV, Section 12, of the Charter of <br />the City of North Olmsted. <br />J T SARINGER, <br />P SIDENT OF COUNCIL <br />First Reading: ? <br />Second Reading: . ? r:r <br />Third Reading: <br />2 <br />PASSED: /? ? <br />4