<br />Ordinance No. 2006-7
<br />(a) Site Survey. A survey of the property including the permanent parcel
<br />numbers, land ownership and existing and proposed topography, street rights of way,
<br />easements, watercourses, floodplains, wetlands, retention basins, property line
<br />dimensions and bearings, surrounding streets and adjoining lots.
<br />(b) Buildings and Structures. The location and size of all main and accessory
<br />buildings or structures as well as ground mounted transformers or mechanical equipment
<br />including the location and outline of buildings on adjoining parcels of land.
<br />(c) Setbacks. Building, service areas, parking lot, and signage setbacks
<br />including front yard, rear yard and side yard areas.
<br />(d) Height Requirements. Maximum height requirements, including
<br />mechanical areas, parapets, etc. shown on building front, rear, and side elevation
<br />drawings.
<br />(e) Parking and Loading, The layout, location, dimensions, number of spaces,
<br />type of pavement, and curbing.
<br />(f) Waste and Refuse. Handling of all waste and refuse materials indicated
<br />and described including appropriate screening and type of containerization.
<br />(g) Streets and Sidewalks. The proposed public and private system of
<br />circulation including automobiles, delivery trucks, emergency vehicles, and pedestrian
<br />details for connection to existing streets and rights of way, methods to control traffic, size
<br />and type of pavement, and proposed names of any street.
<br />(h) Landscaping and Tree Preservation/Removal. Proposed landscaping
<br />including the general landscaping pattern and type of materials, mounding, irrigation, and
<br />fencing; landscape features shown as well as planning dimensions, height and caliper. A
<br />tree plan should also be submitted indicating those trees to be preserved and/or removed
<br />from the site.
<br />(i) Li htin All exterior lighting fixtures including parking lot lighting,
<br />street walkway or pedestrian lighting, walkway accent lighting, and building accent
<br />lighting. Lighting plans shall be incompliance with Section 1161.12 and include:
<br />(1) 10' x 10' illuminance grid (point by point) plot of maintained foot-
<br />candles, carried out to 0.0 foot-candles, which demonstrates compliance with the light
<br />trespass, intensity and uniformity requirements set forth in this section. The maintenance
<br />(light-loss) factor used in calculating the illuminance levels shall be documented on the
<br />plan.
<br />(2) Description of the proposed equipment, including fixture catalog
<br />cuts, photometrics, glare reduction devices, lamps, on/off control devices, mounting
<br />heights, pole foundation details and mounting methods. A pole foundation detail is to be
<br />provided on the plan.
<br />(j) Architectural treatment. Front, rear, and side building elevations shall be
<br />shown."
<br />BE AMENDED AND, AS AMENDED, SHALL READ AS FOLLOWS:
<br />"1126.03 DEVELOPMENT PLAN REQUIREMENTS.
<br />All development plans or parts thereof shall be prepared and submitted by a state
<br />licensed/registered professional such as an engineer, surveyor or architect. The