Laserfiche WebLink
1.08 DELIVERY, STORAGE AND HANDLING <br />A. Deliver products to site in factory sealed cartons and crating bearing the manufacturer's <br />labels. <br />B. Store materials in weather protected environment, clear of ground and moisture, in <br />accordance with manufacturer's instructions. Maintain membranes above 50 degrees <br />Fahrenheit prior to their installation. <br />PART 2 -- PRODUCTS <br />2.01 ACCEPTABLE MANUFACTURERS <br />A. Subject to compliance with the Specifications provide products manufactured by one of the <br />following: <br />1. The Garland Company <br />2. Viridian Systems, Inc. <br />3. Tremco Roofing <br />2.02 SYSTEM DESCRIPTION <br />A. Four ply, hot asphalt applied modified bitumen membrane system with mineral granule <br />surface cap sheet as the fourth ply. <br />2.03 SHEET MATERIALS <br />A. Base Sheets: Glass Fiber 6 Ply Sheet: ASTM D2178, Type VI, UL Type G1 BUR. <br />B. Membrane: Premium, fire - retarding, modified bitumen membrane and surfaced with light <br />colored mineral granules. Cap sheet shall have the following properties: <br />1. Tensile Strength (ASTM D -5147) 450 lbs. <br />2. Tear Strength (ASTM D -5147) 900 lbs. <br />2.04 BITUMINOUS MATERIALS <br />A. Asphalt Bitumen: ASTM D312, Type III. <br />B. Asphalt Primer: ASTM D41, GAF Asphalt/Concrete Primer. <br />C. Asbestos -Free Cement: ASTM D 4586 Type II <br />2.05 INSULATION <br />A. Provide insulation approved by the manufacturer and in accordance with the requirements of <br />Section 07210, Building Insulation. <br />30048 -005: 8,12312012 07510 -3 North Olmsted Phase 2 <br />