My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 2015-091
Document-Host
>
City North Olmsted
>
Legislation
>
2015
>
Resolution 2015-091
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2015 5:39:35 PM
Creation date
10/8/2015 5:39:34 PM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2015-91
Legislation Date
10/6/2015
Year
2015
Legislation Title
WWTP Bldg. 12 Roof Contract Bids
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
twelve foot centers with extruded butyl seal strips. <br /> C. Anchor Plate: Galvanized steel. Anchor to substrate with anchors as recommended by <br /> manufacturer. <br /> D. Finish: Color Anodized in accordance with AA-C22A44, Class 1. *** or Clear Anodized in <br /> accordance with AA-C22A41 or"Baked" on Kynar, with 20 year warranty. <br /> 30048-005: 5/30/2012 07700-3 North Olmsted Phase 2 <br /> E. Guarantees: Twenty year performance guarantees relative to blow-off, leaktightness and <br /> finish. <br /> PART 3 -- EXECUTION <br /> 3.01 INSTALLATION - GENERAL <br /> A. Install roof accessories and specialties in accordance with the manufacturer's instructions. <br /> Provide a complete watertight and weatherproof installation. Install with provision for <br /> expansion and contraction. <br /> 3.02 DAMAGED MATERIAL <br /> A. Repair or replace materials damaged during installation. <br /> 3.03 ADJUSTING AND CLEANING <br /> A. Check levels and adjust as necessary after roofing and flashing is complete. <br /> B. Protect materials from damage by other trades. Remove protective coatings at completion <br /> of project. <br /> - END OF SECTION - <br /> SECTION 07900 <br /> JOINT FILLERS, SEALANTS AND CAULKING <br /> PART 1 -- GENERAL <br /> 1.01 THE REQUIREMENT <br /> A. Furnish labor, materials, equipment and appliances required for the complete execution of <br /> Work shown on the Drawings and specified herein. <br /> 1.02 RELATED WORK SPECIFIED ELSEWHERE <br /> A. Section 03250 - Concrete Accessories <br /> B. Section 03290 - Joints in Concrete <br /> C. Section 04200— Unit Masonry <br /> D. Section 08800 - Glass and Glazing <br /> 1.03 REFERENCE SPECIFICATIONS, CODES AND STANDARDS <br /> A. Without limiting the generality of the other requirements of the specifications, all work herein <br /> shall conform to the applicable requirements of the following documents. All referenced <br /> specifications, codes, and standards refer to the most current issue available at the time of <br /> Bid. <br /> 1. ASTM C-920 Elastomeric Joint Sealants <br /> 2. ASTM D-1056 Flexible Cellular Materials - Sponge or Expanded Rubber <br /> 3. SWRI Sealant and Caulking Guide Specification <br /> 4. Federal Specification TT-S-00227 E <br /> 1.04 SUBMITTALS <br /> A. In accordance with the procedures and requirements set forth in Section 01300 - Submittals, <br /> submit the following: <br /> 1. Manufacturers literature and installation instructions. <br /> 2. Color samples of each type of sealant. <br /> 1.05 QUALITY ASSURANCE <br /> A. Applicator shall be a company specializing in the installation of sealants with a minimum of <br /> five years experience. <br />
The URL can be used to link to this page
Your browser does not support the video tag.