My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-042 Resolution
Document-Host
>
City North Olmsted
>
Legislation
>
2016
>
2016-042 Resolution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2017 10:46:33 AM
Creation date
5/9/2016 3:37:56 PM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2016-042
Legislation Date
5/3/2016
Year
2016
Legislation Title
Bids Demolish and New Building at Site of Former Tank #1 Building at WWTP
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3.03 FIELD QUALITY CONTROL: <br />A. FIELD TESTING: <br />1. An independent testing laboratory acceptable to the Engineer shall be <br />employed by the Contractor to perform the following: <br />a. Qualification of field high strength bolting procedures, field <br />welding procedures and associated personnel. <br />b. Testing of high strength bolt tension. <br />C. Visual inspection of all field welds in accordance with Section 6, <br />Article 605, of the AWS Code. <br />2. At least one bolt in each high strength bolted connection having four bolts <br />or more shall be checked for proper bolt tension by the testing laboratory. <br />At least one bolt in one-third of all high strength bolted connections <br />having less than four bolts shall be checked for proper bolt tension by the <br />testing laboratory. If test bolt tension is not proper, all bolts in that <br />connection shall be checked for improper bolt tension. If more than five <br />(5) percent of connections checked have improper bolt tension, all high <br />strength bolts shall be checked for proper tension on the entire project. <br />B. INSPECTION: <br />1. The Engineer shall be notified and given an opportunity to inspect the <br />completely erected steel frame prior to installation of roof panels or wall <br />panels. <br />2. The Contractor shall afford the Engineer whatever casual labor, platforms, <br />ladders or other access as may be required for proper field review of the <br />work. Such field review shall not relieve the Contractor of his <br />responsibility to furnish materials and workmanship in accordance with <br />the drawings and specifications. <br />2012.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.