D. Block Insulation: Install foamed in place two component thermal insulation in all ungrouted <br />cells of masonry in exterior walls. <br />E. Roofing Insulation: Install roofing insulation in accordance with insulation and roofing <br />manufacturer printed instructions and recommendations. <br />F. Safing Insulation: Install safing insulation in accordance with UL design requirements and in <br />accordance with manufacturer's recommendations. <br />G. Sprayed Polyurethane Foam: Install in strict accordance with manufacturer's <br />recommendations. Separate final installation with code approved thermal barrier. <br />3.03 ADJUSTMENT AND CLEANING <br />A. Adequately protect Work from damage resulting from subsequent construction operations. <br />Replace damaged or soiled Work. <br />- END OF SECTION - <br />SECTION 07600 <br />FLASHING AND SHEET METAL <br />PART 1 -- GENERAL <br />1.01 THE REQUIREMENT <br />A. Furnish labor, materials, equipment and appliances required for complete execution ofWork <br />shown on Drawings and specified herein. <br />1.02 RELATED WORK SPECIFIED ELSEWHERE <br />A. Section 04200 - Unit Masonry <br />B. Section 07510 — Built-up Bituminous Roofing <br />C. Section 07700 — Roof Specialties and Accessories <br />D. Section 07900 - Joint Fillers, Sealants and Caulking <br />1.03 REFERENCES SPECIFICATIONS, CODES AND STANDARDS <br />A. Without limiting the generality of these specifications Work shall conform to the applicable <br />requirements of the following documents: <br />1. OF -506C Flux, Soldering, Paste, and Liquid <br />2. ASTM A176 Stainless and Heat -Resisting Chromium Steel Plate, Sheet and <br />Strip <br />3. ASTM B32 Specifications for Solder Metal <br />4. ASTM D1187 Test Method for Asphalt -Base Emulsions for use as Protective <br />Coatings for Metal <br />5. "Architectural SheetMetalManual" by SheetMetal and Air Conditioning Contractors <br />National Association. <br />1.04 SUBMITTALS <br />A. In accordance with the procedures and requirements set forth in Section 01300 - Submittals, <br />submit the following: <br />1. Manufacturer's literature and installation instructions. <br />2. Complete layout and installation Drawings and schedules with clearly indicated <br />dimensions. <br />3. Color samples. <br />083105BR <br />30048-005: 5/30/2092 07600-2 North Olmsted Phase 2 <br />1.05 DELIVERY, STORAGE, AND HANDLING <br />A. Store materials in a clean dry protected area in such manner to preclude damage by <br />denting, warping, or other distortion. <br />