My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024-083 Resolution
Document-Host
>
City North Olmsted
>
Legislation
>
2024
>
2024-083 Resolution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2024 4:21:36 PM
Creation date
8/21/2024 4:16:25 PM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2024-083
Legislation Date
8/20/2024
Year
2024
Legislation Title
Harrington Battery Back-Ups Dispatch
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Harrington Electric Co. <br />North Olmsted PD Centralized UPS <br />Work Scope and Ouatifications <br />Sonve of Work UPS <br />• Furnish all hardware and related labor to install all raceways, conductors, distribution, <br />bypass, and generator backed feeder, as necessary for the installation of (1) new Liebert <br />20kVA EXM 480/ 208-120 UPS. <br />• Furnish all hardware and related labor to install up to (16) dedicated UPS backed circuits <br />and receptacles- in reference to both the existing and proposed dispatch work station. <br />• Famish all hardware and related labor to install up to (12) dedicated UPS backed circuits <br />and receptacles within the IT/ data mom- in reference to all exiting and possible future IT <br />and communication loads. <br />• Famish all hardware, related labor, and facility coordination to A) commission the newly <br />installed UPS system and prepare for loading, and B) perform circuit migration of the <br />existing in -use loads to the newly installed UPS distribution <br />Scone of Work "Normal" Redundant <br />• Famish all hardware, related labor, and facility coordination to remove and replace the <br />existing obsolete deteriorated 600A service entrance switch, with (1) new Eaton 600A 42 <br />circuit service entrance rated panelboard- to be used as "normal' redundancy to all UPS <br />protected loads. <br />• Famish all hardware and related labor to install (1) 45KVA isolation transformer, and (1) <br />42 circuit 208-120 panelboard within the data room, at or adjacent to the newly installed <br />UPS- to be utilized for "normal' redundant distribution. <br />• Famish all hardware and related labor to duplicated all UPS backed receptacles within the <br />data room- to equip all loads to accept dual source. <br />• Furnish all hardware and related labor to install as necessary, micro switches (Zonnit) to <br />enable single corded devices within the data room to accept dual sources. <br />• Furnish all hardware, related labor, and facility coordination to migrate all single and dual <br />corded devices to the newly install "normal' redundant system. N+1. <br />Ek &drons�on•Vdoe/aataVdeo•nesiDn/auld•2bhour5erda•LotnO 0M8011ml Re tfno <br />Ohb Conn=Uwna No. 11951 <br />
The URL can be used to link to this page
Your browser does not support the video tag.