Laserfiche WebLink
§ 1595.09 <br />DWELLING HOUSE CODE <br />witted under subsections (b) and (c) of this <br />Section. <br />(b) Approved connections. At appliance <br />connections, an approved shut-off valve shall <br />be installed at the end of the house gas pip- <br />ing and shall be located ahead of any tubing <br />serving as an appliance connection. Appli- <br />ances, such as central heating, room heaters, <br />unit heaters, and water heaters, shall be con- <br />nected to the house lines with rigid pipe. <br />Other flue connected appliances, such as gas <br />incinerators, recessed wall heaters and radi- <br />ator heaters in fireplaces, shall be connected <br />to the house lines with rigid pipe, semi-rigid <br />tubing and fittings, or flexible metal tube <br />connectors with a total length of not more <br />than 2 feet. The appliance connection to the <br />house gas piping shall be made with a <br />ground-joint or gasket union located on the <br />appliance side of the shut-off valve. <br />(c) Rigid, semi-rigid and flexible metal <br />tubing. Gas heat appliances which are mov- <br />ed occasionally, such as ranges, refrigerators, <br />clothes driers and hot plates, shall be con- <br />nected to the house lines with rigid pipe, or <br />semi-rigid tubing and fittings, or appliance <br />connectors of flexible metal tubing. When a <br />semi-rigid tubing connector or a flexible <br />metal tubing connector is used, the connec- <br />tion shall be made to a house line outlet in <br />the same room as the appliance. The length <br />of the connector shall not exceed 6 feet and <br />it shall be installed so as to be protected <br />against mechanical injury, <br />(d) Flexible gas hose. Flexible gas hose <br />approved by the Building Official may be <br />used for connecting gas appliances designed <br />for portable use, such as ironers, flatirons, <br />bunsen burners, torches, or other appliances <br />the location of which may be changed prior <br />to or du"ring operation, provided, however, <br />that such flexible gas hose shall not exceed <br />6 feet in length and where such gas hose is <br />used, an approved shut-off valve or gas-cock <br />shall be installed at the point where the gas <br />hose is connected to the house gas piping, <br />Flexible gas hose shall not be concealed from <br />view. No valve shall be installed at the gas <br />inlet to the appliance. <br />(e) Prohibited. joints. Compression, <br />flared, soldered, or sweated joints or fittings <br />shall not be used in gas house piping, but <br />compression or flared fittings may be used <br />for meter connections and at appliance con- <br />nections where exposed to view and observa- <br />tion. <br />1595.09 Size of piping. <br />The piping shall be of such size and so in- <br />stalled as toprovide asupply of gas sufficient <br />118 <br />to meet the maximum demand without loss <br />of more than 0,30 inches water column of <br />pressure between the meter and the appli- <br />ances. In determining the size of the gas pip- <br />ing, due consideration shall be given to fu- <br />ture demands as well as the existing factors <br />and conditions. The main gas supply line <br />and the branch line to any central heating <br />appliance shall be not less than 1-inch di- <br />ameter pipe. Pipe sizes based on the recom- <br />mendations of the AGA Reference Manual <br />for Modern Gas Service and/or the Ameri- <br />can Standard, Installation of Gas Piping and <br />Gas Appliances in Buildings, ASA 221.30, <br />will be accepted as in conformity with this <br />Section. <br />1595.10 Gas piping and meters-restricted <br />locations. <br />(a) Stair enclosures and exitways. No gas <br />meters and no gas piping shall be installed <br />within any stair enclosure or exit passage- <br />way or within any other required means of <br />egress from a building. <br />(b) Obstructed or unventilated locations, <br />Gas meters shall not be installed underneath <br />any stairway, nor in any space which is with- <br />out adequate provisions for ventilation, nor <br />in any location where the use of the space or <br />premises may cause access thereto to be ob- <br />structed, <br />(c) Under basementless floors. Gas serv- <br />ice piping shall not be installed through or <br />under a crawl space under a first floor or <br />basement floor construction, or under a floor <br />laid directly on the ground or fill, except by <br />special permission from the Building Of- <br />ficial. <br />(d) Concealed piping. No pipe smaller <br />than standard 1/z inch iron pipe size shall be <br />used in any concealed location. Concealed <br />piping shall be located in hollow rather than <br />in solid partitions. Piping to be concealed <br />shall not use, unions, running threads, right <br />and left couplings, bushings or swing joints <br />made by combination of fittings. When <br />necessary to insert fittings in piping which <br />has been installed in a concealed location, <br />the piping maybe reconnected by the use of <br />a ground joint union with the nut center- <br />punched or otherwise set to prevent loosen- <br />ing. <br />(e) In solid floors, earth or cinders. Pip- <br />ing in solid floors, such as concrete, shall be <br />laid in channels in the floor suitably covered <br />to permit access to the piping with a mini- <br />mum of damage to the building. Piping in <br />contact with earth or other materials which <br />may corrode the piping shall be protected <br />against corrosion in a manner approved by <br />~ ~ <br />TITLE THREE-ADMINISTRATION <br />CHAPTER 5. BUILDING PERNIITS .AND FEES. <br /> <br />~ ~ <br />1505.01 When required. <br />A building permit shall be obtained from <br />the Building Official before proceeding with <br />any construction, alteration, repair, moving <br />or demolition of any dwelling or appurte- <br />nant structure. A separate permit shall be <br />obtained for electrical work, plumbing work, <br />heating appliances and all other equipment <br />installation that is regulated by this Dwell- <br />ing House Code. <br />1505.02 Application. <br />An application for a permit, signed by the <br />owner or his authorized agent, shall be filed <br />with the Building Official on a form fur- <br />nished. <br />1505.03 Plans and specifications. <br />When required by the Building Official, <br />two or more copies of plans, with specifica- <br />tions either on drawings or as a separate <br />document, shall accompany each application. <br />Each application for a building permit for a <br />new dwelling or alteration amounting to 25% <br />or more of existing buildings shall be ac- <br />companied bytwo sets of plans and specifica- <br />tions, The plans shall include: <br />i. Site plan; showing location on premises; <br />minimum scale: 50'-0" to the inch. <br />ii. Foundation and/or Basement Plan; <br />minimum scale: ~/a"=1'-0". <br />iii. Floor Plan of each other level; mini- <br />mum scale: i/s"=1'-0". <br />iv. Front, rear and side elevations; mini- <br />mum scale: ?/e"=1'-0". <br />v. Sufficient details, to show method of <br />assembly and construction. The above docu- <br />ments shall contain sufficient information to <br />show that the proposed work will conform to <br />the provisions of this Dwelling House Code <br />and all other applicable laws, ordinances, <br />rules and regulations. Each set of plans and <br />specifications shall give the address of the <br />work, name and address of the owner and of <br />the person who prepared them. <br />1505.04 Design data. <br />Sufficient data to show the adequacy of the <br />design shall be submitted when required by <br />the Building Official. The Building Official <br />may require and accept an affidavit from a <br />registered architect or registered profes- <br />sional engineer, stating that the design con- <br />forms to the provisions of this Dwelling <br />House Code. <br />1505.05 Issuance of permit. <br />(a) Approval. If the Building Official is <br />satisfied that the work described in an ap- <br />plication for a permit and the plans and <br />specifications filed therewith conform to and <br />comply with the requirements of this Dwell- <br />ing House Code and other pertinent laws and <br />ordinances, upon payment of the required <br />fee he shall issue or authorize the issuance of <br />a permit] <br />(b) Disapproval. If the application for a <br />permit, and the plans and specifications filed <br />therewith, describe work which does not <br />conform to the requirements of this Dwelling <br />House Code or other pertinent laws or ordi- <br />nances or does not contain sufficient infor- <br />mation, the Building Official shall not issue <br />a permit but shall return the plans and <br />specifications to the applicant with his re- <br />fusal to issue such permit. The Building <br />Official shall give in writing such reasons for <br />rejection as he deems sufficient. <br />1505.06 Conditions of the permit. <br />A permit issued shall be construed to be <br />a license to proceed with the work. It shall <br />not be construed as authority to violate, can- <br />cel, alter or set aside any of the provisions <br />of this Dwelling House Code or other ap- <br />plicable laws, ordinances, rules or regula- <br />tions, nor shall such issuance of a permit <br />prevent the Building Official from thereafter <br />requiring a correction of errors in plans or <br />in construction, or of violations of this Dwell- <br />ing House Code or of other applicable laws, <br />ordinances, rules or regulations. The Build- <br />ing Official shall not incur any personal <br />liability or expense or impose any liability <br />or expense upon the Municipality by virtue <br />of his prior approval of any plan or specifi- <br />cation later determined by him or any other <br />authority to be in contravention of this <br />Dwelling House Code or other applicable <br />laws, ordinances, rules or regulations. <br />1505.07 Approved plans. <br />When -the permit is issued, the Building <br />Official shall endorse in writing or stamp on <br />all sets of plans and specifications, "AP- <br />PROVED," with date and signature. Such <br />approved plans and specifications shall' not <br />be changed, modified, or altered in any man- <br />ner affected by this Dwelling House Code <br />without authorization from the Building Of- <br />ficial and all work shall be done in accord- <br />ance with the approved plans and specifica- <br />~ Provided the plans have been approved by the Architectural Board of Revie~', <br />as requi ed by lJrdinance lio. 360 and Amendments there'w® <br />