Laserfiche WebLink
§ 1505.08 <br />DWELLING HOUSE CODE <br />8 <br />tions. One set of approved plans sand specifi- <br />cations shall be retained by the Building <br />Official; one approved set shall be kept at the <br />site of work at all times while the work is in <br />progress and shall be open to inspection at all <br />reasonable times by the Building Official or <br />his authorized representative. <br />1505.08 Time limitation. <br />Any permit issued shall become invalid <br />unless the work authorized by it shall have <br />been commenced within six months after its <br />issuance or if the work authorized by such <br />permit is suspended or abandoned for a <br />period of one year after the time the work <br />is commenced; provided that for cause, one <br />or more extensions of time for periods not <br />exceeding ninety days each may be allowed <br />in writing by the Building Official. <br />1505.09 Work started without a permit. <br />Where work, for which a permit is re- <br />quired by this Dwelling House Code, is <br />started prior to obtaining such permit, the <br />fees required by said permit shall be doubled <br />but the payment of such double fee shall <br />not relieve any person from fully complying <br />with the requirements of this Dwelling <br />House Code or any other law of the State of <br />Ohio or ordinance of this Municipality. <br />1505.10 Permit fees. <br />The Building Official shall authorize the <br />issuance of the permits required by this <br />Dwelling House Code after the determina- <br />tion by him of the fees due and the deposits <br />to be made in accordance with the ordinances <br />of this Municipality. <br />~: CHAPTER 7. INSPECTION. <br />1507.01 Right of entry. <br />Upon presentation of proper credentials, <br />the Building Official may enter at reasonable <br />times any building, structure, or premises in <br />the Municipality to perform any duty im- <br />posed upon him by this Dwelling House <br />Code. <br />1507.02 Existing buildings. <br />Before issuing a permit, the Building Of- <br />ficialmay examine the building for which an <br />application has been received for permit to <br />enlarge, alter, repair, move or demolish. <br />1507.03 At site. <br />The Building Official shall inspect all <br />building construction at the intervals or <br />periods stated in Section 1561.04 and inspect <br />such building at any time and from time to <br />time as he may determine as necessary or <br />desirable. <br />1507.04 AEpoinf.,ofmanufacture. <br />When deemed necessary by the Building <br />Official, he shall make an inspection of ma- <br />terials and assemblies at the point of man- <br />ufacture or fabrication. <br />1507.05 Inspection organization. <br />The Building Official may accept reports <br />of inspectors of accredited inspecting organi- <br />zations, but no approval called for by any <br />provision of these requirements shall be <br />based on such reports unless the same are in <br />writing and certified by a responsible officer <br />of such organization. <br />CHAPTER 9. PENALTIES FOR VIOLATION, <br />1509.01 Stop orders. <br />Upon notice from the Building Official <br />that work on any building or structure is <br />being done contrary to the provisions of this <br />Dwelling House Code or in a dangerous or <br />unsafe manner, such work shall be immedi- <br />ately stopped.. Such notice shall be in writ- <br />ing and shall state the reason for stopping <br />the work and the conditions under which <br />the work may be resumed, and such notice <br />shall be delivered to the owner of the prop- <br />erty,. or to .his agent, or to the person in <br />charge of the work at the site. <br />1509.02 Revocation of permit. <br />The Building Official may revoke a permit <br />or approval issued under the provisions of <br />this Dwelling House Code in case there has <br />been any false statement or misrepresenta- <br />tion as to a material fact in the application <br />or plans on which the permit or approval <br />was based. <br />1509.03 Criminal action. <br />Any person, firm or corporation violating <br />any of the provisions,of this Dwelling House <br />Code shall be deemed guilty of a misde- <br />~ ~ <br />~ ~ <br />• ~ <br />117 <br />Gas Piping and Appliances <br />drawing shall be submitted with the applica- <br />tionfor apermit, showing the proposed loca- <br />tion of the piping as well as the size of the <br />different branches. <br />1595.03 Approved standards for equipment <br />and installations. <br />(a) General. All house piping and all gas- <br />fired appliances shall be installed in con- <br />formity with the requirements of this Dwell- <br />ing House Code and in conformity with ac- <br />cepted safe practice. <br />(b) Safe practice. Except as provided in <br />this Dwelling House Code or in statutes, or <br />in regulations promulgated by authority of <br />statute, or in other ordinances, conformity <br />with the requirements of the following <br />Standards will be recognized as conformity <br />with accepted safe practice: <br />1. Standards of the National Board of Fire <br />Underwriters for the Installation of Gas Pip- <br />ing and Gas Appliances in Buildings, NBFU <br />Pamphlet No. 54. <br />2. Listing, Approval and Installation Re- <br />quirements for gas burning appliances and <br />accessories, as listed in Section 1591.07. <br />3. Approval Requirements for Domestic <br />Gas Ranges-ASA 221.1, Z21,1a, <br />4. Listing Requirements for Flexible Gas <br />Tubing-ASA 221.2. <br />5. Approval Requirements for Refrigera- <br />tors Using Gas Fuel-ASA 221.19. <br />6. Listing Requirements for Semi-Rigid <br />Gas Appliance Tubing and Fittings-ASA <br />221.24. <br />7. Listing Requirements for Attachable <br />Gas Water Heating Units-ASA 22126. <br />8. Installation of Gas Piping and Gas Ap- <br />pliances in Buildings-ASA 221.30, <br />9. Approval Requirements for Gas Coun- <br />ter-Appliances-ASA 221.31. <br />10. Listing Requirements for Gas Appli- <br />ance Connectors of Flexible Metal Tubing <br />and Fittings-ASA 221.32. <br />(c) Power of Board. The Board of Build- <br />ing Code Appeals may change, modify, or <br />supplement any of the requirements of such <br />Standards when deemed necessary in the in- <br />terests of public safety or to further define <br />accepted safe practice. <br />1595.04 Approval of materials. <br />(a) Basis for approval. All gas piping, <br />tubing, fittings, accessories, appurtenances, <br />and gas appliances shall;be of a type con- <br />forming to the Standards set forth in Section <br />1595.03 or which have .been listed or ap- <br />proved by UL, AGA, or:by. other accredited <br />§ 1595.08 <br />agencies or by the Board of Building Code <br />Appeals. <br />(b) Seal o f approval or listing symbol, No <br />person shall connect or install within the <br />Municipality any piping, tubing, fitting, ac- <br />cessory, gas appliance or appurtenance, <br />which does not bear the seal of approval or <br />listing symbol of Underwriters' Laboratories, <br />Inc., or the American Gas Association, or <br />other accredited agency. <br />1595.05 Curb cock and main shut-off. <br />(a) Curb cock. All gas service piping <br />shall be equipped with an approved curb <br />cock placed in an accessible location outside <br />of the building. <br />(b) Main shut-o);f cock. Every system of <br />gas house piping shall have an accessible <br />main piping shut-off cock located immedi- <br />atelyadjacent to, and on the service pipe side <br />of, the meter. <br />1595.06 Installation and connection of gas- <br />fired appliances. <br />(a) Support and connection. Every gas- <br />firedappliance shall be adequately supported <br />and so connected to the house gas piping as <br />not to exert undue strain on the connection. <br />(b) Clearance for access and operation. <br />Every gas-fired appliance shall be so located <br />as to be readily accessible for operation and <br />adjustment and shall have the clearances <br />from combustible material or construction <br />specified in the Standards Listed in Sections <br />1591,07 and 1595.03 to which the appliance <br />conforms. When the clearance distance has <br />not been otherwise established, the Building <br />Official may prescribe the required clearance <br />distance, <br />1595.07 Control of pilot on automatic gas <br />water heaters. <br />Every automatically controlled gas water <br />heater shall have as part of its construction <br />or assembly an automatic device to shut off <br />the gas to the main burner or burners when- <br />ever the flame of the pilot is extinguished. <br />1595.08 Gas piping and connections. <br />(a) Materials. All house gas piping shall <br />be so constructed and installed as to be dur- <br />able, substantial, and gas-tight. House gas <br />piping shall be of standard weight wrought <br />iron or steel pipe with malleable iron <br />threaded fittings, or iron-pipe-size copper <br />pipe with threaded copper fittings, or iron- <br />pipe-size brass pipe with threaded brass fit- <br />tings, or other approved rigid piping and fit- <br />tings. Flexible gas hose or semi-rigid appli- <br />ance connectors may be used where per- <br />fj. <br />