Laserfiche WebLink
§ 1593.92 <br />DWELLING HOUSE CODE <br />(b) Building ,drains, and sewers, The <br />building drain, building sewer and yard and <br />area drains, including all piping to a height <br />of 2 feet above the highest point of the <br />building drain, shall be tested separately. All <br />traps, pipe fittings and joints shall be ex- <br />posed to view when the test is made. Water <br />shall be introduced into the system at a test <br />tee designated by the Building Official and <br />in such quantity as deemed necessary by <br />him. To be approved, the flow of water <br />through the system shall be unobstructed <br />and there shall be rio leakage through any <br />pipe, joint, trap, or fitting. <br />1593.92 ,Air test of drainage and vent <br />system. <br />The air test shall be made by attaching an <br />air compressor or testing apparatus to any <br />suitable opening and after closing all other <br />inlets to the system, forcing air into the sys- <br />temuntil there is a uniform gage pressure of <br />5 psi, or sufficient to balance a column of <br />mercury 10 inches in height. This pressure <br />shall be held. without the introduction of ad- <br />ditional air for a period of at least 15 <br />minutes. Wooden plugs shall not be used to <br />close opening. ,,, <br />1593.93 Smoke and peppermint test. <br />A smoke test shall be made by filling all <br />traps with water and then introducing into <br />the entire drainage and vent system a pun- <br />gent thick smoke produced by one or more <br />smoke machines. When the smoke appears <br />at stack openings .on the roof they shall be <br />closed and a pressure equivalent to a 1-inch <br />water column shall be built up and main- <br />tained for 15 minutes before inspection <br />starts. A peppermint test shall be made by <br />introducing at least 2 ounces of oil of pepper= <br />116 <br />mint for each line or stack. To be approved, <br />the system shall reveal no lack of trap seal <br />at any point and there shall be no evidence <br />of smoke or peppermint leaking from the <br />system. <br />1593.94 Test ofwater-supply systems. <br />Upon the completion of a section or of an <br />entire water-supply system, it shall be tested <br />and proved tight under awater-pressure not <br />less than the working pressure under which <br />it is to be used. The water used for test shall <br />be obtained from the normal source of sup- <br />P1Y <br />1593.95 Test of interior leaders or down- <br />spouts. <br />Leaders or downspouts and branches with- <br />in abuilding shall be tested by water or air <br />as specified for drainage and vent systems. <br />1593.96 Covering work not tested and ap- <br />proved. <br />The plumbing system or any part thereof <br />slall not be covered until it has been in- <br />spected, tested, and approved as prescribed <br />in Chapter 93. <br />1593.97 Certiflcate of approval. <br />Upon the satisfactory completion and final <br />test of the plumbing system, a certificate of <br />approval shall be issued to the plumber by <br />the Building Official. <br />1593.98 Test of defective or unsanitary <br />plumbing. <br />Where, in the 'opinion of the Building Of- <br />ficial, the drainage and vent system of any <br />building has become unsanitary or defective, <br />such drainage and vent system shall be sub- <br />jected to a smoke or peppermint test. <br />CHAPTER 95. GAS PIPING AND APPLIANCES. <br />1595.01 Scope and application. <br />(a) General. The provisions of this chap- <br />ter shall govern the installation, alteration, <br />and replacement of gas piping; and the in- <br />stallation, except venting, of gas-fired ap- <br />pliances (other than space heating appliances <br />and incinerators) such as ranges, hot plates, <br />countertop-type cooking equipment, ovens, <br />broilers and other ,cooking and baking ap- <br />pliances; water heaters, clothes driers, <br />ironers and refrigerators. <br />(b) Exceptions. Provisions governing gas- <br />fired space heating appliances, incinerators, <br />chimneys, flues, and gas vents are included <br />in Chapters 59 and 91; however, gas piping <br />to such space heating appliances and in- <br />cinerators shall be installed in conformity <br />with provisions of this Chapter 95. <br />1595.02 Permits and drawings. <br />(a) Requirement. A permit shall be re- <br />quired for the installation, alteration, or re- <br />placement of house gas piping or for the in- <br />stallation of gas-fired appliances required by <br />this Dwelling House Code to have a flue or <br />vent connection. <br />(b) Drawings. Whenever necessary to in- <br />dicate or explain the installation of a gas <br />piping system, alteration, replacement or re- <br />pair, or its relation to existing facilities, a <br /> <br />9' Building Official; Board of Appeals <br />meanor and upon the conviction of any such <br />violation such person shall be punishable by <br />a fine of not more than $300.00 or by im- <br />prisonment of not more than three months <br />or by both such fine and imprisonment. Such <br />person, firm or corporation shall be deemed <br />guilty of a separate offense for each and <br />every day or portions thereof during which <br />any violation of any of the provisions of this <br />Dwelling House Code is committed, con- <br />tinued or permitted. <br />1509.04 Civil Action. <br />Whenever any person, firm or corporation <br />fails, neglects or refuses to comply with any <br />order of the Building Official under the pro- <br />visions of Section 1509.01 or 1509.02, or <br />whenever any budding or other structure is <br />used or occupied so as to be iri violation of <br />CHAPTER 11. B <br />~ ~ <br />X511.01 Rules and regulations. <br />The Building Official may promulgate such <br />rules and regulations .as he may determine <br />as necessary to supplement or aid in the in- <br />terpretation of the requirements of this <br />Dwelling House Code, which regulations <br />shall be consistent therewith. <br />§ 1513.02 <br />or not in conformity with any provision of <br />this Dwelling House Code, the Building Of- <br />ficial may in his discretion institute and <br />maintain in the name of the Municipality an <br />appropriate action at law or in equity to re- <br />strain the execution iri violation of this, <br />Dwelling House Code, to prevent the occupa- <br />tion or use of such building or other struc- <br />ture and to prevent or terminate any viola- <br />tion of this Dwelling House Code. <br />1509.05 Remedies cumulative. <br />The exercise. of the rights and remedies <br />granted in Sections 1509.01 through 1509.04, <br />shall in no way preclude or limit the Munic- <br />ipality from exercising any other right or <br />remedy now or hereafter granted to it under <br />the laws of the State of Ohio or the ordi- <br />nances of this Municipality. <br />UILDING OFFICIAL. <br />shall have the same force and effect as provi- <br />sions of this ordinance. <br />1511.04 Amendment of rules. <br />Any rule may be amended or replaced by <br />the same procedure as prescribed for the <br />adoption of new rules. <br />1.511.02 Publication of rules. <br />No rule of the Building Official shall be- <br />come effective until two weeks after notice <br />of intention to enforce it shaf 1 have been <br />posted on at least two bulletin boards in <br />public places of the Municipality. Any per- <br />son may, in writing, during the period that <br />said proposed rule is posted, appeal to the <br />Board of Building Code Appeals, alleging <br />that.said proposed rule is unreasonable, ar- <br />bitrary; confiscatory or contrary to the pro- <br />visions of this Dwelling House Code. <br />1511.03 Effect of rules. <br />Rules promulgated as herein provided <br />1511.05 Liability. <br />Neither the Building Official nor any per- <br />son appointed or employed by him when act- <br />ing in good faith and without malice shall be <br />personally liable for damages by reason of <br />anything done under the provisions of this <br />Dwelling House Code. <br />1511.06 Records and reports. <br />The Building Official shall keep or cause <br />to be kept a record of. the business of the <br />Building,,Department. The records of the <br />Building Department shall be open to public <br />inspection during regular business hours. <br />CHAPTER 13. BOARD OF BUILDING CODE APPEALS. <br />1513.01 Appointment. <br />' There is hereby established in the munic- <br />ipality aBoard to be known as the Board of <br />Building Code Appeals, consisting of five <br />members who are qualified by experience <br />and training to pass upon matters pertain- <br />ing to building construction who shall be <br />appointed. by the Mayor of the municipality. <br />1513.02 Tenure. <br />One member of the Board shall be ap- <br />pointed for a term of one year, one member <br />for a term of two years, one member for a <br />term of three years, one member for a term <br />of four years, and one member for a term <br />of five years. Upon expiration of the term of <br />office of a member of the Board, his succes- <br />