Laserfiche WebLink
§ 1513.03 <br />DWELLING HOUSE CODE <br />10 <br />sor shall be appointed for a term of five <br />years. Vacancies shall be filled for an unex- <br />pired term in the manner in which the orig- <br />inal appointments are required to be made. <br />Continued absence of any member from reg- <br />ular meetings of this Board shall render any <br />such member liable to immediate removal <br />from office. <br />1513.03 Quorum. <br />Three members of the Board shall con- <br />stitute aquorum. In varying the application <br />of any provision of this Dwelling House Code <br />or in modifying an order of the Building <br />Official, affirmative votes of three members <br />shall be required. <br />1513.04 Disqualification. <br />No member of the Board shall pass upon <br />any question in which he has a financial or <br />personal interest. On such appeals or ques- <br />tions in which a member is disqualified or <br />asks to be excused, the Mayor shall appoint <br />an alternate to fill the temporary vacancy, <br />1513.05 Compensation. <br />The Council shall, at the start of each year, <br />set the compensation of the members of the <br />Board of Building Code Appeals for the time <br />served at Board meetings. <br />1513.06 Powers. <br />The Board of Building Code Appeals shall <br />have the power, subject to the limitations <br />and in the manner set forth in this Dwelling <br />House Code, to: <br />i. Affirm or reverse, in whole or in part, <br />or modify, any decision of the Building Of- <br />ficial interpreting the provisions of this <br />Dwelling House Code; <br />ii. Vary the application of any provision <br />of this Dwelling House Code to any par- <br />ticular case, when, in its opinion, enforce- <br />ment thereof would do manifest injustice, <br />would be contrary to the spirit and the pur- <br />pose of this Dwelling House Cade or the <br />public interest; <br />iii. Determine if any material or method of <br />construction may be used, even though not <br />specifically authorized by this Dwelling <br />House Code, and specify the manner in <br />which such materials and methods shall be <br />used; <br />iv, Determine any requirement for the <br />strength or stability of an existing or pro- <br />posed building or structure, or for the <br />safety or health of the occupants thereof, not <br />specifically covered by this Dwelling House <br />Code, or not readily interpretable from the <br />provisions of this Dwelling House Code; - <br />v. Determine whether any proposed rule <br />of the Building Official supplements or aids <br />in the interpretation of the requirements of <br />this Dwelling House Code and is consistent <br />therewith, and to affirm, amend, modify or <br />nullify any such proposed rule. <br />vi. Establish rules and regulations, condi- <br />tions and qualifications for the registration, <br />licensing or certification of qualification of <br />any person performing work or providing <br />services under this Dwelling House Code. <br />vii. Report and recommend to the Council <br />any amendment, deletion or addition to this <br />Dwelling House Code. <br />1513.07 Meetings and records. <br />Meetings of the Board shall beheld at the <br />call of the chairman and at such other times <br />as the Board may determine. All hearings <br />before the Board shall be open to the public. <br />The Board shall keep minutes of its pro- <br />ceedings, showing the vote of each member <br />upon every question, or if absent or failing <br />to vote, indicating such facts, and shall also <br />keep records of its examinations and other <br />official actions. Such minutes and such rec- <br />ordsshall bepublic records. <br />1.513.08 Procedure. <br />The Board shall establish rules and reg- <br />ulations for its own procedure not incon- <br />sistent with the provisions of this Dwelling <br />House Code. It shall also establish a sched- <br />ule of fees that may be required for filing <br />designated types of appeals. The Board mem- <br />bers shall annually, by majority vote, select <br />one of the members to serve as chairman, <br />who shall hold office for a term of one year <br />or until his successor is elected and qualified. <br />1513.09 Reports. <br />The Board shall submit a report to the <br />Mayor and Council not less than once a year <br />covering the meetings and a summary of the <br />decisions of the Board during the preceding, <br />period, with recommendations as to desirable <br />amendments to this Dwelling House Code or <br />the Building Official's rules and regulations. <br />A copy of such report shall be sent to the <br />Regional Board of Building Standards. <br />1513.10 Alternative Board. <br />In lieu of the Board created with the <br />duties and powers set forth in Sections <br />1513.01 through 1513.09, the Mayor may, <br />with the consent of the Council, designate <br />any Administrative Board or Commission <br />created by the charter or any ordinance of <br />this Municipality to carry out and perform <br />the duties charged upon the Board of Build- <br />w <br />~ ~ <br />~ ~ <br />115 <br />Plumbing <br />drainage system through an air-gap serving <br />the individual fixtures, devices, appliances <br />or apparatus: <br />i. A refrigerator, ice-box, steam table or <br />other receptacle, appliance, device or appa- <br />ratus which is used for the storage, prepara- <br />tion or processing of food or drink. <br />ii. An appliance, device or apparatus using <br />water as a cooling or heating medium. <br />iii. Appliances, devices or apparatus such <br />as sterilizers or water stills. <br />iv. Water treatment devices such as filters <br />or softeners and water operated devices; and <br />drains, overflows or vents from water-supply <br />systems. <br />1593.87 Permissible indirect waste. <br />(a) Laundry trays. The waste from a <br />laundry tray or trays may discharge into a <br />trapped floor drain. <br />(b) Scum gutters and surface drains <br />around swimming pools. Scum gutters, scum <br />gutter drains and floor drains serving walks <br />around swimming pools may be installed <br />with indirect waste. <br />(c) Bar, counter or laboratory sinks. <br />Small bar, counter, laboratory sinks and <br />other small fixtures, determined by the <br />Building Official to be of similar type, maybe <br />installed with indirect waste where direct <br />waste connections are impracticable and in- <br />direct waste connections are specifically ap- <br />proved by the Building Official. Where in- <br />direct wastes are approved, such fixtures <br />shall be trapped but no individual vent will <br />be required. <br />(d) Clear water wastes. Clear water <br />wastes, water lifts, expansion tanks, cooling <br />jackets, sprinkler systems, drip or overflow <br />pans or similar devices which wastes clear <br />water only may discharge onto a roof, into <br />a sump, or into a trap or fixture. <br />1593.88 Inspections and tests. <br />(a) Request. It shall be the responsibility <br />of the person, to whom the plumbing permit <br />has been issued, to give 24 hours advance <br />notice to the Building Official when plumb- <br />ing work is ready for test or inspection. <br />When proper notice has been given and the <br />test or inspection has not been made, the <br />work may proceed without waiting on such <br />test or inspection, but no work shall be <br />covered or concealed without specific au- <br />thorization to do so from the Building Of- <br />ficial. <br />(b) Preliminary test. It shall be the re- <br />sponsibility__of_ the person to whom-the <br />plumbing permit has been issued to conduct <br />a preliminary test in order to make certain <br />§ 1593.91 <br />that the work will stand the prescribed test <br />before making the request required in sub- <br />section (a) of this section. <br />(c) Retesting and reinspection. If the <br />Building Official finds that the work does <br />not pass the test or inspection, the person <br />to whom the plumbing permit has been is- <br />sued shall be required to make the necessary <br />corrections and the fork shall then be re- <br />submittedfor test or inspection. <br />1593.89 Material and labor for tests. <br />The equipment, material, power and labor <br />necessary for inspection or test shall be fur- <br />nished by the person to whom the permit is <br />issued. <br />1593.90 Testing drainage and vent systems. <br />The piping of drainage and vent systems <br />shall be tested with water or air. After the <br />plumbing fixtures have been set and their <br />traps filled with water, the entire drainage <br />system shall be submitted to a final inspec- <br />tion. The Building Official may require the <br />removal of cleanouts or plugs or unsealing <br />of traps to ascertain whether the test medium <br />has reached all parts of the system. Where <br />there is reason to doubt conformity with the <br />provisions of this chapter, the whole plumb- <br />ing system shall be submitted to a smoke or <br />peppermint test. <br />1593.91 VOater test of drainage and vent <br />systems. <br />(a) Drainage and vent stacks and <br />branches. The water test shall be applied to <br />the drainage and vent system in its entirety <br />or in sections. If applied to the entire <br />system, all openings in the piping shall be <br />tightly closed, except the highest opening, <br />and the system filled with water to the <br />point of overflow. If the system is tested <br />in' sections, each opening shall be tightly <br />plugged except the highest opening of the <br />section under test, and each section shall <br />be filled with water, but no section, except <br />the building drain and building sewer and <br />its connected yard and area drains, shall be <br />tested with less than a 10-foot head of water. <br />In testing successive sections above the <br />building drain, at least the upper 10 feet of <br />the next preceding section shall be retested <br />so that no joint or pipe in the building, ex- <br />cept the uppermost 10 feet of the system, <br />shall have been submitted to a test of less <br />than 10-foot head of water. The water shall <br />be kept in the system, or in the portion un- <br />der test, far at least 15 minutes before in-- - <br />spection starts. The system shall be water <br />tight. <br />