~ 1593.83 <br />DWELLING HOUSE CODE <br />a backwater trap, area drain, yard drain, or <br />sand intercepter trap. <br />(c) Basement water-closets. No vent shall <br />be required for awater-closet or floor drain <br />at the cellar or basement level discharging <br />directly into a building drain at least 5 feet <br />from any soil or waste stack connection, pro- <br />vided: <br />i. The fixture unit load on the building <br />drain and building sewer at any point along <br />-the building drain and the building sewer <br />does not exceed z/s that permitted by Table <br />93D, and, <br />ii. Where the discharge is into a combined <br />building drain or building sewer, the total <br />load on the combined building drain or build- <br />ing sewer does not exceed z/s the total load <br />permitted by-Table 93E. <br />(d)' Flat-bottom fixtures. Aflat-bottomed <br />fixture, such as a kitchen sink, dishwasher, <br />bathtub, laundry tray, combination fixture, <br />shower stall, or floor drain, discharging <br />through a "P" trap or in the case of a bath- <br />tub through a "P" trap or drum trap, may be <br />installed at a level not exceeding 12 feet <br />above the crown level of a building drain <br />and connected to the building drain without <br />venting the fixture trap, provided: <br />i. The connection is at least 5 feet from <br />any soil or waste stack connection, and <br />ii. The fixture drain is one pipe size larger <br />than the fixture outlet and trap but not less <br />than 2-inch, and <br />iii. The developed length of the fixture <br />drain, from trap weir to end of base ell, <br />does not exceed 15 feet, and <br />iv. Provided further that the fixture unit <br />load on the .building drain and building <br />sewer at any point along the building drain <br />and building sewer does not exceed ~/s that <br />permitted by Table 93D, and, where the <br />discharge is into a combined building drain <br />or building sewer, the total load on the <br />combined building drain or building sewer, <br />the total load on the combined building drain <br />or building sewer does not exceed z/s the <br />total load permitted by Table 93E. <br />(e) Minor fixtures. Those fixtures re- <br />quiring traps of 2-inch diameter or less, lo- <br />cated on the first floor and more than 5 feet <br />from a stack, will not require venting, pro- <br />vided the waste pipe from such fixture is <br />not less than 2 inches, and the developed <br />Iength of such waste pipe does not exceed <br />fifteen feet. <br />114 <br />will not require venting, provided the waste <br />pipe from such fixtures is not less than 2 <br />inches and the developed length of such <br />waste pipe does not exceed 15 feet. <br />1593.83 Main vents to connect at base. <br />All main vents or vent stacks shall connect <br />full size at their base to the main soil or <br />waste pipe, at or below lowest fixture branch, <br />and shall extend undiminished in size above <br />the roof or shall be reconnected with the <br />main soil or waste vent above the highest <br />fixture. <br />1593.84 Size of vents. <br />(a) Vent stack. A vent stack or main <br />vent shall have a diameter of at least one- <br />half the diameter of the soil or waste stack, <br />but in no case less than 1~/4 inches and, de- <br />pending upon the number of fixture-units in- <br />~stalled on the soil or waste stack, shall be in <br />accordance with the following Table 93G. <br />TABLE 93G. <br />SIZE OF VENT PIPES. <br />Size of Pipe <br />(Inches) lI/4' 11/z" 2" 21/z" 3" <br />Maximum <br />Number of <br />Fixture-units 2 8 20 40 60 <br />(b) Stack vent. Diameter of a stack vent <br />shall be not less than the diameter of the <br />soil or waste stack of which it is an exten- <br />sion, <br />(c) Individual or dual vent. The diameter <br />of an individual or dual vent shall be not less <br />than 1~/4 inches nor less than one-half the <br />required diameter of the drain to which it <br />is connected. <br />1593.85 Minimum sizes of vents. <br />The minimum size of vents for typical <br />plumbing fixtures for dwelling houses shall <br />be as follows: <br />TABLE 93H. <br />MINIMUM SIZES OF VENTS. <br />Fixtures Size <br />Bathtub, with or without shower ____ lr/4" <br />Kitchen sink, above first floor ______ 1~/4" <br />Shower stall ______________________ 1~/z" <br />Water closet _______________________ 11/z" <br />Bathroom group consisting of 1 lava- <br />tory, 1 water closet, 1 bathtub or <br />shower stall _____________________ 1~/2" <br /> <br /> <br />• <br /> <br />(f) Alteration work. In alteration work, 1593.86 Required indirect waste piping. <br />fixtures requiring traps of 2-inch diameter or Waste from the following fixtures and ap- <br />less and located on first floor or basement, pliances shall discharge into the building <br />11 <br />Board of Building Code Appeals <br />§ 1513.12 <br />ing Code Appeals by this Dwelling House <br />Code, and upon such designation by the <br />Mayor and confirmation by the Council, such <br />other Board or Commission shall be vested <br />with all the powers granted to such Board <br />of Building Code Appeals by this Dwelling <br />House Code or by the charter or other ordi- <br />nance of this Municipality. <br />1513.11 Appeal to board. <br />Any person or any municipal officer or <br />official or any public body aggrieved by the <br />action of the Building Official may take an <br />appeal to the Board of Building Code Ap- <br />peals. The Building Official or any munici- <br />pal officer or official or any public body, or <br />any member of the Board of Building Code <br />Appeals, may request a hearing by the <br />Board on any subject over which said Board <br />has jurisdiction or power, as set forth in <br />this Dwelling House Cade, or may request <br />the Board to review or interpret any provi- <br />sion of this Dwelling House Code. <br />1513.12 Time, fee and notice of appeal. <br />An appeal from any decision of the Build- <br />ing Official may be taken within thirty days <br />from the date of the decision from which the <br />appeal is taken by paying the required fee <br />and filing with the Building Official and with <br />the Board a notice of appeal, specifying the <br />grounds therefor. The Building Official shall <br />forthwith transmit to the Board papers upon <br />which the action appealed was taken. <br />1513.13 Action on appeals, hearings and <br />reviews. <br />(a) Notice. The Board shall hold a public <br />hearing on each appeal and shall give such <br />notice to the Building Official and other in- <br />terestedparties as the Board shall direct and <br />shall give such notice to the public by post- <br />ing, publication or otherwise as the Board <br />shall deem appropriate. At the hearing, any <br />party may appear in person, or by his agent <br />or attorney. <br />(b) Evidence and inspection. In passing <br />upon appeals, the Board of Building Code <br />Appeals may require submission of evidence <br />or proof to substantiate claims, and may re- <br />quire such additional data and tests which, <br />in the opinion of the Board, are needed for <br />adequate consideration of the appeal. Any <br />member of the Board or any person author- <br />ized by the Board may at any time enter, <br />inspect and examine any plans, building or <br />structure for the purpose of carrying out <br />the duties of the Board. <br />1513.14 Decisions general. <br />The Board of Building Code Appeals shall <br />in every case reach a decision without un- <br />reasonable or unnecessary delay. Every de- <br />cision of the Board shall be in writing and <br />shall indicate the vote upon a decision. <br />Every decision shall be promptly filed in <br />the office of the Building Official and shall <br />be open to public inspection. A certified <br />copy shall be sent by mail or otherwise to <br />the appellant or other interested party and <br />a copy shall be kept publicly posted in the <br />office of the Building Official for two weeks <br />after filing. <br />1513.15 Variations and modifications. <br />The Board of Building Code Appeals, <br />after public hearing, may vary the applica- <br />tion of any provision of this Dwelling House <br />Code to' any particular case when, in its <br />opinion, enforcement thereof would do mani- <br />fest injustice, would be contrary to the spirit <br />and purpose of this Dwelling House Code or <br />public interest or when, in its opinion, the <br />interpretation of the Building Official should <br />be modified or reversed. A decision of.the <br />Board to vary the application of any provi- <br />sion of this Dwelling House Code or to <br />modify an order of the Building Official shall <br />specify in what manner such variation or <br />modification is made, the conditions upon <br />which it is made and the reasons therefor. <br />1513.16 Building Ofcial to take actflon. <br />If a decision of the Board of Building <br />Code Appeals reverses or modifies a refusal, <br />order or disallowance of the Building Offi- <br />cial or varies the application of any provi- <br />sion of this Dwelling House Code, the Build- <br />ing Official shall take action immediately in <br />accordance with such decision. <br />1513.17 Regional Board of Building Stand- <br />ards. <br />)n order to provide uniformity in the in- <br />terpretation of the provisions of this Dwell- <br />ing House Code and a central agency for <br />determining the suitability of new materials <br />and types and methods of construction, the <br />Board of Building Code Appeals may by a <br />majority vote refer to the Regional Board of <br />Building Standards, established pursuant to <br />the resolution adopted by the Regional <br />Planning Commission, for its consideration <br />and recommendation, any Building Code <br />matter that may come to its attention. Any <br />decision, ruling or recommendation of the <br />Regional Board of Building Standards shall <br />not be binding upon any Municipal Official <br />or body. <br />