Laserfiche WebLink
the hardships for the applicant was that drive-in restaurants were not taken into consideration <br />when the code was written. Mr. Mackey was concerned about ingress and egress to Lorain Road. <br />Mr. Papotto did not believe that the sight triangle would be an issue since Lorain Road is angled <br />along the property. <br />Mr. Allain moved, seconded by Mr. Papotto, to grant the following variances for 17-9636; <br />Swensons; 27175 Lorain Road, contingent upon the lot consolidation of parcels 235-01-001, <br />-002, -003, -084 and -085: <br />Al. A 37 ft. variance permitting a building in the required front setback; code requires 75 <br />ft., applicant shows 38 ft.; Section 1139.04(B). . <br />A2. A variance permitting parking areas in required street lawns and buffer zones; code <br />prohibits parking areas from being located in any required street lawn and buffer zone, <br />applicant shows parking in prohibited areas; Section 1139.04(D). <br />A3. A 15.13 ft. variance for street lawn depth; code requires 20 ft., applicant proposes 4.87 <br />ft. Section 1139.05(B)(1)(c). <br />A4. A 20 ft. variance for buffer zone depth adjacent to residential property; code requires <br />30 ft. when adjacent to One Family Residence district, applicant shows 10 ft.; Table <br />1139.06-3. <br />A5. A 3.13 ft. variance for buffer zone depth adjacent to commercial property; code <br />requires 10 ft. when adjacent to any commercial district, applicant shows 6.87 ft.; Table <br />1139.06-3. <br />A6. An 11 ft. variance for light pole setback from a residential property line; code requires <br />poles with a mounting height of 16 ft. to be set back at least 30 ft. from a residential <br />property line, applicant shows a setback of 19 ft.; Section 1161.10(D)(1). Note: 3 poles <br />are shown in the required setback area. <br />A7. A variance permitting a dumpster enclosure in a required buffer area; code prohibits <br />dumpsters in required buffer areas; Section 1161.11(A). <br />B1. A variance permitting a ground sign in the required 35 ft. sight triangle area; code <br />prohibits signs from being installed in the 35 ft. sight triangle area; Section 1163.17(A). <br />B2. A 213.71 sq. ft. variance for total sign area on a building; code permits 53.20 sq. ft., <br />applicant shows 266.91 sq. ft.; Section 1163.25(B). <br />B3. A variance permitting 1 additional ground sign; code permits 1 ground sign, applicant <br />shows 2; Section 1163.27(A). <br />B4. A variance permitting 8 additional wall signs on a building; code allows 2 wall signs, <br />applicant shows 10; Section 1163.28(A). <br />B5. A variance permitting two wall signs to extend closer than 12 in. to the top edge of a <br />wall; code requires a minimum distance of 12 in. from the top of a sign to the top of the <br />wall to which it is attached, applicant shows sign projection above the wall.; Section <br />1163.28(B). Note Swenson's Main Sign on Elevation A. <br />B6. A 2.23 ft. height variance for 1 wall sign; code allows a maximum height of 4 ft., <br />applicant shows 6.23 ft.; Section 1163.28(C). Note Swenson's Main Sign on Elevation A. <br />B7. A 1.5 ft. height variance for 2 wall signs; code allows a maximum height of 4 ft., <br />applicant shows 5.5 ft.; Section 1163.28(C). Note Proposed Menu Board signs on <br />Elevations B and C. <br />B8. A 1 ft. height variance for 2 wall signs; code allows a maximum height of 4 ft., applicant <br />shows 5 ft.; Section 1163.28(C). Note Limited Time Offer signs on Elevations B and C. <br />B9. A variance permitting two wall signs less than 2 ft. apart; code requires wall signs to be