My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001-096 Resolution
Document-Host
>
City North Olmsted
>
Legislation
>
2001
>
2001-096 Resolution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2014 10:57:06 AM
Creation date
1/15/2014 10:01:11 AM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2001-096
Legislation Date
7/18/2001
Year
2001
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Specifications <br />Electrical cord or conduit shall be supported within six (6) inches (152 n1m) of any junction <br />boa and at a minimum of even, 24 inches (610 mm) of continuous run. Supports shall be <br />made of nonmetallic materials or corrosion protected metaL All supports shall be of a design <br />that does not cut or abrade the conduit or cable and shall be mechanically fastened to the <br />vehicle. <br />Wirin? Identification <br />A11 line voltage conductors ]ocated in the main panel board shall be individually and <br />pennanently identified. The identification shall reference the wiring schematic or indicate the <br />final termination poin±. When prewiring for future power sources or devices; the <br />unternlinated ends shall be labeled showing function and wire size. <br />Wet Locations <br />All wet location receptacle outlets and inlet devices, inclucting those on hardwired remote <br />power distribution boxes, shall be of the grounding type provided with a wet location cover <br />and installed in accordance with Section 210-7 "Receptacles and Cord Connections" of the <br />NEC. <br />All receptacles located in a wet location shall be not less than 24 inches (610 rmn) from the <br />ground. Receptacles on off-road velucles shall be a minimum of 30 inches (762 mm) from <br />the --round. <br />The face of any wet location receptaele shall be installed in a plane from vertical to not more <br />than 45 degrees off vertical. No receptacle shall be installed in a face up position. <br />Drv Locations All receptacles located in a drv location shall be of tne grounding t_ype. Receptacles shall be <br />not less than 30 inches (762 mm) above the interior floor height. <br />All receptacles sha11 be marked xith the type of line voltage (120-volts or 240-volts) and the <br />cuz7ent rating in amps. If the receptacles are direct cun-ent, or other than single pliase, they <br />shail be so marked. <br />ListinL, <br />A11 receptacles and electrical iniet devices shall be listed to UL, 498, Standard for Safety <br />Attachznent Plugs and Receptacles, or other appropriate performance standards. Receptacles <br />used for direct current volta?es shall be rated for the appropriate sernice. <br />Electrical Svstem Testin? <br />The wiring and associated equipment shall be tested by the apparatus manufacturer or the <br />installer of the line voltage system. <br />The wiring and peimanently connected devices and equipment shall be subjected to a <br />dielectric voltage withstand test of 900-volts for one (1) minute. The test shall be conducted <br />Bidder <br />Complies <br />Yes I No <br />Page 67
The URL can be used to link to this page
Your browser does not support the video tag.