permitted for townhouses if such walls do not contain plumbing or <br />mechanical equipment, ducts or vents in the cavity of the common wall. <br />Electrical installations are limited to electrical wire installed in metallic <br />raceways and metallic electrical outlet boxes. Metallic electrical outlet boxes <br />shall not exceed 16 square inches in surface area. The aggregate surface <br />area of the boxes shall not exceed 100 square inches for any 100 square feet <br />of wall area. Metallic outlet boxes on opposite sides of walls shall be <br />separated by a minimum distance of 24 inches. Metallic electrical outlet <br />boxes shall be installed in accordance with their listings. <br />15. Sec 306-Daman oo f The first paragraph of Section R-306.1 <br />is hereby amended to read as follows: <br />Exterior foundation walls of masonry construction enclosing basements shall <br />be dampproofed by applying not less than 3/8 inch portland cement parging <br />to the wall from footing to finish grade. The parging shall be covered with <br />a coat of approved bituminous material applied at the recommended rate. <br />Exterior foundation walls of concrete construction enclosing basements shall <br />be dampproofed by applying a coat of approved bituminous material to the <br />wall from the footing to six inches above the finished grade at the <br />recommended rate. <br />16. sec 323 Protection Asr in D AYa_nd Te~rmmit~c (mil The following <br />sentence is added to Section R 323.1: The top row of concrete block on the <br />foundation must be solid type block to prevent termites from infesting the <br />building. <br />17. Table 503 2 la Allowable Spans and Loads for Plywood and Wo©d <br />Struc urai_ Pa_rrpls for Roof and Subfloor Sheathinst and Conte lon <br />Subfloor Underlayment (,Amendedl. Delete any references in the <br />NOMINAL PANEL THICKNESS column to any thickness less than 7/16 <br />of an inch. <br />18. ~~^ S~5 Concrete Floors (Qn Ground~~pd~d1 505.1 Ste: <br />Concrete slab-on-ground floors shall be constructed in accordance with <br />Figure No. 403.1a. The specified compressive strength of concrete at 28 <br />days shall be not less than 2,500 pounds per square inch except where <br />weather exposure requires greater strength and air-entrained concrete, as set <br />forth in Table No. 402.2. <br />Slabs shall be constructed with control joints having a depth of at least one- <br />fourth the slab thickness, and joints shall be spaced at intervals not more <br />than 30 feet in each direction and slabs not rectangular in shape shall have <br />control joints across the slab at points of offset if offset exceeds 10 feet. <br />Sec. 505.2.2 : Eliminate "crushed blast-furnace slag gassing a 2-inch <br />(Slmm) sieve" as an option. <br />EXCEPTION: Deleted <br />... <br />!Y_R4t ya7jyggyg-ew~.; ~,.... ...^Yt.N1~...... <br />.:,,y .. <br />