Legislation Title
Bids Roof Replacement WWTP Building No. 14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
twelve foot centers with extruded butyl seal strips. <br />C. Anchor Plate: Galvanized steel. Anchor to substrate with anchors as recommended by <br />manufacturer. <br />D. Finish: Color Anodized in accordance with AA-C22A44, Class 1. *** or Clear Anodized in <br />accordance with AA-C22A41 or "Baked" on Kynar, with 20 year warranty. <br />30048-005: 5/30/2012 07700-3 North Olmsted Phase 2 <br />E. Guarantees: Twenty year performance guarantees relative to blow -off, leaktightness and <br />finish. <br />PART 3 -- EXECUTION <br />3.01 INSTALLATION - GENERAL <br />A. Install roof accessories and specialties in accordance with the manufacturer's instructions. <br />Provide a complete watertight and weatherproof installation. Install with provision for <br />expansion and contraction. <br />3.02 DAMAGED MATERIAL <br />A. Repair or replace materials damaged during installation. <br />3.03 ADJUSTING AND CLEANING <br />A. Check levels and adjust as necessary after roofing and flashing is complete. <br />B. Protect materials from damage by other trades. Remove protective coatings at completion <br />of project. <br />- END OF SECTION — <br />SECTION 07900 <br />JOINT FILLERS, SEALANTS AND CAULKING <br />PART 1 -- GENERAL <br />1.01 THE REQUIREMENT <br />A. Furnish labor, materials, equipment and appliances required for the complete execution of <br />Work shown on the Drawings and specified herein. <br />1.02 RELATED WORK SPECIFIED ELSEWHERE <br />A. Section 03250 - Concrete Accessories <br />B. Section 03290 - Joints in Concrete <br />C. Section 04200 — Unit Masonry <br />D. Section 08800 - Glass and Glazing <br />1.03 REFERENCE SPECIFICATIONS, CODES AND STANDARDS <br />A. Without limiting the generality of the other requirements of the specifications, all work herein <br />shall conform to the applicable requirements of the following documents. All referenced <br />specifications, codes, and standards refer to the most current issue available at the time of <br />Bid. <br />1. ASTM C-920 Elastomeric Joint Sealants <br />2. ASTM D-1056 Flexible Cellular Materials - Sponge or Expanded Rubber <br />3. SWRI Sealant and Caulking Guide Specification <br />4. Federal Specification TT -S-00227 E <br />1.04 SUBMITTALS <br />A. In accordance with the procedures and requirements set forth in Section 01300 - Submittals, <br />submit the following: <br />1. Manufacturers literature and installation instructions. <br />2. Color samples of each type of sealant. <br />1.05 QUALITY ASSURANCE <br />A. Applicator shall be a company specializing in the installation of sealants with a minimum of <br />five years experience. <br />