My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-062 Resolution
Document-Host
>
City North Olmsted
>
Legislation
>
2016
>
2016-062 Resolution
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2017 10:45:03 AM
Creation date
6/23/2016 5:30:18 PM
Metadata
Fields
Template:
North Olmsted Legislation
Legislation Number
2016-062
Legislation Date
6/21/2016
Year
2016
Legislation Title
Bids Roof Replacement WWTP Building No. 14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Attachment 1: 2016 Lab Building Roof Specifications: <br />All roofing systems shall conform to the building specifications Contained in <br />the May 2012 WWTP Phase 2 Improvements- Contract A as specified <br />below: <br />Hazen and Sawyer, Engineers for the City of North Olmsted WWTP <br />Improvement Project, Phase 2. <br />SECTION 07510 <br />BUILT-UP BITUMINOUS ROOFING <br />PART 1 -- GENERAL <br />1.01 THE REQUIREMENT <br />A. Furnish all labor, materials, equipment and appliances required for the complete execution <br />of Work shown as specified herein. <br />1.02 RELATED WORK SPECIFIED ELSEWHERE (see below) <br />A. Section 06100 - Rough Carpentry <br />B. Section 07210 - Building Insulation <br />C. Section 07600 - Flashing and Sheet Metal <br />D. Section 07700 - Roof Specialties and Accessories <br />1.03 REFERENCE SPECIFICATIONS, CODES, AND STANDARDS <br />A. Without limiting the generality of these specifications Work shall conform to the applicable <br />requirements of the following documents: <br />1. ASTM D41 Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing. <br />2. ASTM D312 Asphalt Used in Roofing. <br />3. ASTM D2178 Asphalt Felt Used in Roofing and Waterproofing. <br />4. FS HH-1-1972/GEN Insulation Board, Thermal, Faced, Polyurethane or <br />Polyisocyanurate. <br />1.04 SUBMITTALS <br />A. In accordance with the procedures and requirements, submit the following: <br />1. Product data for glass fiber ply sheet, modified bitumen sheet membrane, insulation and base <br />flashing materials. <br />2. Manufacturer's installation instructions. <br />3. Certification that materials meet or exceed specified requirements. <br />4. Certification that installer is approved by the manufacturer. <br />5. Copy of manufacturer's 20 year system warranty. <br />6. Samples of each product. <br />7. Color samples of cap sheet. <br />8. Field report at the end of all roofing and related work. <br />1.05 QUALITY ASSURANCE <br />A. Applicator: Company well experienced in modified bitumen roofing membrane application <br />and approved by product manufacturer. <br />B. Products and installation shall be in accordance with the following: <br />1. Underwriters Laboratories, Inc. (UL): Class A Fire Hazard Classification. <br />2. Factory Mutual Engineering Corporation (FM): Roof assembly classification, FMRC, Approval <br />Standard 4470, Class I, and 1-90 approvals. <br />3. Design roof to meet wind design criteria in the Ohio Building Code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.